Task setting
Automatic mode
1) Connect the charger to an AC outlet (100-240V)
or a 12V vehicle adapter.
2) Insert a battery into the C4 while observing the
correct polarity and once the battery has been identi ed
charging will commence and the charging screen will
appear to display the charging state (as below)
1
Mj.Jpo
3
297nBi
5
11;24;19
7
8
96
3
9
10
Interface
1.Battery type
2. Operation status
3. Capacity charged
4. Present voltage & current
5. Task operation time
6. Resistance & temperature
7. Voltage curve
8. Taskbar
9. Battery charge %
10. Battery discharge %
11. Charging nished
12. Battery circulate %
The taskbar shows the status of each task visually.
means charging
means circulate, analyze. After any task is complet-
ed, the
will be displayed on the screen instead of
the battery percentage. You can cycle between the
detailed task pages by using the up and down arrow
buttons.
2
Dibshjoh
4
5/1:W!0!1/91B
6
96n℃!0!4:-
80
11
12
means discharge,activate,
manual mode
Place a battery into a suitable charging slot and the
charger will start charging automatically (if set to auto
start by default). Alternatively users could press the
touch key to remain on the task page and change each
parameter manually. The options are as follows:
BB0S70VN.4025611
Cbuufsz
Ubtl
Dvssfou
Dzdmf
Tubsu
Cbdl
99
3
Battery types
Select battery type
Task
Select task content: Charge,Discharge,Storage,Cycle,Activation,Analysis
Current setting
Select current:charge/storage:0.1-3.0A;discharge:0.1A-1.5A
cycle index
cycle index:1-66
Start task
Start to execute task
Back
Back
How to con rm battery types
Usually, the battery chemistry type and the rated voltage
is stated on the sleeve of the battery. The charger will
attempt to automatically identify the battery type based
on the built-in detection algorithm but please select the
battery types manually if the charger chooses the wrong
one.
* NiZn and LiHv batteries need to be selected manually.
Default battery types and task parameters
NiCd/NiMH
NiZn
Rated Voltage
1.20V
1.5V
Full charge voltage
1.65V
1.9V
Storage voltage
X
X
Discharge voltage
0.90V
1.20V
Default charging current: AAA/10440-0.5A
The default charging current is automatically selected
according to the length of a battery. Please select the
current manually if the battery has a long length and
small capacity, for example 14650/16650 etc.
Dibshf
Ejtdibshf
Tupsbhf
Dzdmf
Bdujwbujpo
Bobmztjt
3.6
Li-lon
LiHv
LiFePo4
Eneloop
3.70V
3.80V
3.30V
1.20V
4.2V
4.35V
3.65V
1.65V
3.70V
3.80V
3.20V
X
3.10V
3.30V
2.90V
0.90V
AA/10500-1A
18650-2A
26650-2.5A
03 | English