Ferroli DIVAtech F 32 D Instrucciones De Uso, Instalación Y Mantenimiento
Ferroli DIVAtech F 32 D Instrucciones De Uso, Instalación Y Mantenimiento

Ferroli DIVAtech F 32 D Instrucciones De Uso, Instalación Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 12

Enlaces rápidos

D D IVAtech F 32 D
400
IT - ISTRUZIONE PER L'USO L'INSTALLAZIONE E LA MANUTENZIONE
ES - INSTRUCCIONES DE USO, INSTALACIÓN Y MANTENIMIENTO
TR - KULLANMA, KURULUM VE BAK M TALIMATLAR
EN - INSTRUCTIONS FOR USE, INSTALLATION AND MAINTENANCE
FR - INSTRUCTIONS D'UTILISATION, D'INSTALLATION ET D'ENTRETIEN
RO - INSTRUC IUNI DE UTILIZARE, INSTALARE I ÎNTRETINERE
RU -
UA -
330
,
,
115
85
85
115
80
80.5
51
54
76
58.5
F E
D
C
B
A
A
C
E
B
D
F

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Ferroli DIVAtech F 32 D

  • Página 1 D D IVAtech F 32 D 80.5 58.5 IT - ISTRUZIONE PER L’USO L'INSTALLAZIONE E LA MANUTENZIONE ES - INSTRUCCIONES DE USO, INSTALACIÓN Y MANTENIMIENTO TR - KULLANMA, KURULUM VE BAK M TALIMATLAR EN - INSTRUCTIONS FOR USE, INSTALLATION AND MAINTENANCE FR - INSTRUCTIONS D'UTILISATION, D'INSTALLATION ET D'ENTRETIEN RO - INSTRUC IUNI DE UTILIZARE, INSTALARE I ÎNTRETINERE RU -...
  • Página 2: Accensione E Spegnimento

    Quando la caldaia viene spenta, la scheda elettronica è ancora alimentata elettricamen- DIVAtech F 32 D è un generatore termico per riscaldamento e produzione di acqua cal- te. È disabilitato il funzionamento sanitario e riscaldamento. Rimane attivo il sistema an- da sanitaria ad alto rendimento funzionante a gas naturale, dotato di bruciatore atmosfe- tigelo.
  • Página 3: Disposizioni Generali

    DIVAtech F 32 D Regolazione della temperatura ambiente (con termostato ambiente opzionale) Regolazione pressione idraulica impianto Impostare tramite il termostato ambiente la temperatura desiderata all’interno dei locali. La pressione di caricamento ad impianto freddo, letta sull’idrometro caldaia (part. 17 - Nel caso non sia presente il termostato ambiente la caldaia provvede a mantenere l’im-...
  • Página 4: Collegamenti Elettrici

    DIVAtech F 32 D 3.5 Collegamenti elettrici Avvertenze L’apparecchio deve essere collegato ad un efficace impianto di messa a terra eseguito come previsto dalle vigenti norme di sicurezza. Far verificare da per- sonale professionalmente qualificato l’efficienza e l’adeguatezza dell’impianto di terra, il costruttore non è responsabile per eventuali danni causati dalla man- canza di messa a terra dell’impianto.
  • Página 5 IMPORTANTE - IL LOCALE DEVE ESSERE DOTATO DI VENTILAZIONE APPROPRIATA Se si intende collegare la caldaia DIVAtech F 32 D ad una canna fumaria collettiva o ad un camino singolo a tiraggio naturale, canna fumaria o camino devono essere espres- samente progettati da personale tecnico professionalmente qualificato in conformità...
  • Página 6: Messa In Servizio

    DIVAtech F 32 D 4. SERVIZIO E MANUTENZIONE A - Presa di pressione a monte 4.1 Regolazioni B - Presa di pressione a valle Trasformazione gas di alimentazione I - Connessione elettrica Valvola gas R - Uscita gas L’apparecchio può funzionare con alimentazione a gas Metano o G.P.L. e viene predi- S - Entrata gas sposto in fabbrica per l’uso di uno dei due gas, come chiaramente riportato sull’imballo...
  • Página 7: Risoluzione Dei Problemi

    DIVAtech F 32 D Codice Anomalia Possibile causa Soluzione anomalia Cablaggio interrotto Verificare il cablaggio Anomalia valvola gas Verificare ed eventualmente sostitu- Valvola gas difettosa ire la valvola gas Verificare ventilatore e cablaggio ven- Anomalia ventilatore tilatore Anomalia controllo combu-...
  • Página 8: Circuito Idraulico

    DIVAtech F 32 D 5. CARATTERISTICHE E DATI TECNICI 5.2 Circuito idraulico Tabella. 9 - Legenda figure cap. 5 5 Camera stagna 38 Flussostato 7 Entrata gas 39 Limitatore di portata acqua 8 Uscita acqua sanitaria 42 Sensore di temperatura sanitaria...
  • Página 9 DIVAtech F 32 D 5.3 Tabella dati tecnici 5.4 Diagrammi Diagrammi pressione - potenza Dato Unità DIVAtech F 32 D Portata termica max 34.4 Portata termica min 11.5 Potenza Termica max riscaldamento 32.0 Potenza Termica min riscaldamento Potenza Termica max sanitario 32.0...
  • Página 10: Schema Elettrico

    DIVAtech F 32 D 5.5 Schema elettrico LC32 ABM01 ° ° ° 230V 50 Hz fig. 21 - Circuito elettrico Attenzione: Prima di collegare il termostato ambiente o il cronocomando re- moto, togliere il ponticello sulla morsettiera. cod. 3541A770 - 10/2011 (Rev. 00)
  • Página 11: Certificato Di Garanzia

    • La presente garanzia si aggiunge e non pregiudica i diritti dell’acquirente previsti dalla direttiva 99/44/CEE e relativo decreto nazionale di attuazione. FERROLI S.p.A. - Via Ritonda 78/a - 37047 San Bonifacio (Verona) Italy - tel. +39.045.6139411 - fax. +39.045.6100933 - www.ferroli.it...
  • Página 12: Encendido Y Apagado

    2.1 Presentación fig. 2 - Apagado de la caldera DIVAtech F 32 D es un generador térmico de alto rendimiento para calefacción y pro- ducción de agua caliente sanitaria, alimentado con gas natural y dotado de quemador Cuando la caldera se apaga, la tarjeta electrónica permanece conectada. Se inhabilitan la produc- atmosférico con encendido electrónico, cámara estanca de ventilación forzada y siste-...
  • Página 13: Disposiciones Generales

    DIVAtech F 32 D Regulación de la temperatura ambiente (con termostato de ambiente opcional) Regulación de la presión hidráulica de la instalación Mediante el termostato de ambiente, programar la temperatura deseada en el interior de La presión de carga con la instalación fría, leída en el higrómetro de la caldera (17 - la vivienda.
  • Página 14: Conexiones Eléctricas

    DIVAtech F 32 D 3.5 Conexiones eléctricas Advertencias El equipo se debe conectar a una toma de tierra eficaz, según lo establecido por las normas de seguridad. Solicitar a un técnico especializado que controle la eficacia y la compatibilidad de la instalación de tierra. El fabricante no se hace responsable por daños debidos a la falta de puesta a tierra de la instala-...
  • Página 15 IMPORTANTE - EL LOCAL DEBE ESTAR DOTADO DE VENTILACIÓN APROPIADA. Si se desea conectar la caldera DIVAtech F 32 D a una chimenea colectiva o a una in- dividual con tiro natural, la chimenea debe estar diseñada por un técnico cualificado, con arreglo a las normas vigentes, y ser adecuada para equipos de cámara estanca dotados...
  • Página 16: Puesta En Servicio

    DIVAtech F 32 D 4. SERVICIO Y MANTENIMIENTO A - Toma de presión aguas arriba 4.1 Regulaciones B - Toma de presión aguas abajo Cambio de gas I - Conexión eléctrica de la válvula del gas R - Salida de gas El equipo puede funcionar con gas metano o GLP.
  • Página 17: Solución De Problemas

    DIVAtech F 32 D Código Anomalía Causa posible Solución anomalía Sensor averiado Anomalía del sensor de ida Controlar el cableado o cambiar el Cableado en cortocircuito sensor Cableado interrumpido Cableado interrumpido Controlar el cableado Anomalía de la válvula del Controlar la válvula del gas ycam- Válvula del gas averiada...
  • Página 18: Circuito Hidráulico

    DIVAtech F 32 D 5. CARACTERÍSTICAS Y DATOS TÉCNICOS 5.2 Circuito hidráulico Tabla. 9 - Leyenda de las figuras cap. 5 5 Cámara estanca 38 Flujostato 7 Entrada de gas 39 Limitador del caudal de agua 8 Salida de AS...
  • Página 19: Tabla De Datos Técnicos

    DIVAtech F 32 D 5.3 Tabla de datos técnicos 5.4 Diagramas Diagramas presión - potencia Dato Unidad DIVAtech F 32 D Capacidad térmica máxima 34.4 Capacidad térmica mínima 11.5 Potencia térmica máx. en calefacción 32.0 Potencia térmica mín. en calefacción Potencia térmica máxima en ACS...
  • Página 20: Esquema Eléctrico

    DIVAtech F 32 D 5.5 Esquema eléctrico LC32 ABM01 ° ° ° 230V 50 Hz fig. 21 - Circuito eléctrico Atención: Antes de conectar el termostato de ambiente o el reloj programa- dor a distancia, quitar el puente de la regleta de conexiones.
  • Página 21: Certificado De Garantía

    Certificado de garantia Llene por favor la cupón unida Polígono Industrial de Villayuda Apartado de Correos 267 - 09007 Burgos Tel. 947 48 32 50 Fax 947 48 56 72 e.mail: ferroli@ferroli.es FACSIMILE http//www.ferroli.es Dirección Comercial: Avda. Italia, 2 28820 Coslada (Madrid) Tel.
  • Página 22: Açma Ve Kapatma

    Kombi kapatıldı ı zaman, elektronik kartta halen elektrik akımı bulunmaktadır. Sıcak su DIVAtech F 32 D do al gaz ile çalı an ve elektronik ate lemeli bir brülör, havalandırmalı ve ısıtma i lemleri devre dı ı bırakılır. Antifriz sistemi aktif kalır. Kombiyi tekrar yakmak su geçirmez bölmeli, sistem kontrolünü...
  • Página 23: Genel Talimatlar

    DIVAtech F 32 D Ortam sıcaklı ının ayarlanması (opsiyonel ortam termostatı ile) Su sistemi basınç ayarlaması Ortam termostatını kullanarak sıcaklık de erini oda için istenilen de ere ayarlayınız. Sistem so uk haldeyken kombinin hidrometresinden okunan doldurma basıncı (kısım 17 E er ortam termostatı monte edilmi de il ise, kazan, sistemi ayarlanmı olan sistem - ek.
  • Página 24 DIVAtech F 32 D 3.5 Elektrik ba lantıları Uyarılar Cihaz, mevcut standartlara uygun bir ekilde verimli ve etkin bir topraklama si- stemine do ru bir ekilde ba lanmalıdır. Mesleki açıdan kalifiye bir personele, topraklama sisteminin verimlili ini ve de uygunlu unu kontrol ettiriniz; imalatçı, topraklama sistemindeki arıza nedeniyle meydana gelecek hasarlardan dolayı...
  • Página 25 ÖNEML - KURULUM YER UYGUN HAVALANDIRMAYA SAH P OLMALIDIR Dolayısıyla, e er DIVAtech F 32 D kombisini do al çekimli olan bir toplayıcı bacaya veya tekli bacaya ba layacaksanız, yürürlükteki normlar uyarınca bacanın tasarımının ke- sinlikle profesyonel açıdan kalifiye bir personele yaptırılması ve fan ile donatılmı...
  • Página 26 DIVAtech F 32 D 4. SERVIS VE BAK M A - Kar ı akıntı basınç noktası 4.1 Ayarlamalar B - Akı yönünde basınç noktası Gaz temini dönü ümü I - Gaz valfı elektrik ba lantısı R - Gaz çıkı ı...
  • Página 27: Sorunların Giderilmesi

    DIVAtech F 32 D Arıza Olası neden Çözüm arıza Kablolarda kopukluk var Kablo tesisatını kontrol ediniz Gaz valfında anormallik Kontrol ediniz ve gerekirsegaz valfını Arızalı gaz valfı de i tiriniz Fanıve fan kablo ba lantılarını kontrol Fan arızası ediniz Kontrol ediniz ve gerekirsediyaframı...
  • Página 28: Hidrolik Devre (Su Devresi)

    DIVAtech F 32 D 5. ÖZELLIKLER VE TEKNIK VERILER 5.2 Hidrolik devre (Su devresi) Çizelge 9 - ekil açıklamaları cap. 5 5 Yanma odası 38 Akı -sivici 7 Gaz giri i 39 Su kapasitesi sınırlayıcı 8 Sıhhi su çıkı ı...
  • Página 29 DIVAtech F 32 D 5.3 Teknik veriler tablosu 5.4 Diyagramlar Basınç - güç diyagramları Veri Birim DIVAtech F 32 D Maks. termik kapasite 34.4 Min. termik kapasite 11.5 Isıtma maksimum termik gücü 32.0 Isıtma minimum termik gücü Sıcak su maksimum termik gücü...
  • Página 30 DIVAtech F 32 D 5.5 Elektrik eması LC32 ABM01 ° ° ° 230V 50 Hz ek. 21 - Elektrik devresi Dikkat: Ortam termostatını veya uzaktan kumandalı zamanlayıcı kontrolünü takmadan önce terminal blo undaki konnektörü çıkartınız. cod. 3541A770 - 10/2011 (Rev. 00)
  • Página 32: Control Panel

    The antifreeze system remains activated. To relight the boiler, press the on/off button (detail 7 fig. 1) again for 5 seconds. DIVAtech F 32 D is a high-efficiency heat generator for heating and domestic hot water production, running on natural gas, equipped with an open-flue burner with electronic ig-...
  • Página 33: Place Of Installation

    DIVAtech F 32 D Room temperature adjustment (with optional room thermostat) System water pressure adjustment Using the room thermostat, set the temperature required in the rooms. If the room ther- The filling pressure with system cold, read on the boiler water gauge (detail 17 - fig. 1), mostat is not installed, the boiler will keep the system at the set system delivery setpoint must be approx.
  • Página 34: Electrical Connections

    DIVAtech F 32 D 3.5 Electrical connections Important The unit must be connected to an efficient earthing system in conformity with current safety regulations. Have the efficiency and suitability of the earthing system checked by professionally qualified personnel; the Manufacturer de- clines any liability for damage caused by failure to earth the system.
  • Página 35 IMPORTANT - THE ROOM MUST BE PROVIDED WITH APPROPRIATE VENTILATION If the boiler is to be connected DIVAtech F 32 D to a collective flue or a single flue with natural draught, the flue or chimney must be expressly designed by professionally qual- ified technical personnel in conformity with the current regulations and be suitable for sealed chamber units equipped with fan.
  • Página 36 DIVAtech F 32 D 4. SERVICE AND MAINTENANCE A - Upstream pressure point 4.1 Adjustments B - Downstream pressure point Gas conversion I - Gas valve electrical connection R - Gas outlet The unit can operate on natural gas or LPG and is factory-set for use with one of these S - Gas inlet two gases, as clearly shown on the packing and on the dataplate.
  • Página 37: List Of Faults

    DIVAtech F 32 D Code Fault Possible cause Cure fault Fan fault Check the fan and fan wiring Check the baffle and replace it if nec- Faulty baffle Combustion control fault essary Flue not correctly sized or Check the flue...
  • Página 38: Water Circuit

    DIVAtech F 32 D 5. TECHNICAL DATA AND CHARACTERISTICS 5.2 Water circuit Table. 9 - Key of figures cap. 5 5 Sealed chamber 38 Flowswitch 7 Gas inlet 39 Water flow limiter 8 Domestic hot water outlet 42 DHW temperature sensor...
  • Página 39: Technical Data Table

    DIVAtech F 32 D 5.3 Technical data table 5.4 Diagrams Pressure - power diagrams Data Unit DIVAtech F 32 D Max. heating capacity 34.4 Min. heating capacity 11.5 Max. Heat Output in heating 32.0 Min. Heat Output in heating Max. Heat Output in hot water production 32.0...
  • Página 40: Wiring Diagram

    DIVAtech F 32 D 5.5 Wiring diagram LC32 ABM01 ° ° ° 230V 50 Hz fig. 21 - Electrical circuit Important: Before connecting the room thermostat or the remote timer con- trol, remove the jumper on the terminal block. cod. 3541A770 - 10/2011 (Rev. 00)
  • Página 41: Allumage Et Extinction

    2. INSTRUCTIONS D'UTILISATION 2.1 Introduction DIVAtech F 32 D est un générateur thermique de chauffage et de production d'eau chaude sanitaire à haut rendement fonctionnant au gaz naturel ; équipé d'un brûleur at- mosphérique à allumage électronique, d'une chambre étanche à ventilation forcée et d'un système de contrôle par microprocesseur, il peut être installé...
  • Página 42: Dispositions Générales

    DIVAtech F 32 D Réglage de la température ambiante (avec thermostat d'ambiance en option) Réglage de la pression hydraulique de l'installation Programmer à l'aide du thermostat d'ambiance la température souhaitée à l'intérieur des pièces. La pression de remplissage, à installation froide, lue sur l'hydromètre de la chaudière Si le thermostat d'ambiance n'est pas monté, la chaudière maintiendra l'installation à...
  • Página 43: Raccordements Électriques

    DIVAtech F 32 D 3.5 Raccordements électriques Avertissements La sécurité électrique de l'appareil ne peut être assurée que lorsque celui-ci est correctement raccordé à une ligne de mise à la terre efficace conforme aux nor- mes en vigueur. Faire vérifier par un professionnel qualifié l'efficacité et la con- formité...
  • Página 44 à tirage naturel IMPORTANT - LE LOCAL DOIT ÊTRE DOTÉ D'UN DISPOSITIF DE VENTILATION APPROPRIÉ Pour raccorder la chaudière DIVAtech F 32 D à un carneau collectif ou individuel à ti- rage naturel, ces derniers doivent être conçus par un technicien professionnellement qualifié, conformément aux normes en vigueur et être appropriés aux appareils à...
  • Página 45: Mise En Service

    DIVAtech F 32 D 4. UTILISATION ET ENTRETIEN A - Prise de pression en amont 4.1 Réglages B - Prise de pression en aval Transformation du gaz d'alimentation I - Connexion électrique soupape de gaz R - Sortie gaz L'appareil peut fonctionner au gaz naturel ou gaz liquide, et est prédisposé en usine pour S - Arrivée gaz...
  • Página 46: Liste Des Anomalies

    DIVAtech F 32 D Code Anomalie Causes probables Solution anomalie Capteur endommagé Contrôler le câblage ou remplacer le Anomalie capteur départ 2 Câblage en court-circuit capteur Câblage interrompu Câblage interrompu Vérifier le câblage Anomalie vanne à gaz Vérifier et remplaceréventuellement la Vanne à...
  • Página 47: Circuit Hydraulique

    DIVAtech F 32 D 5. CARACTÉRISTIQUES ET DONNÉES TECHNIQUES 5.2 Circuit hydraulique Tableau 9 - Légende des figures cap. 5 5 Chambre étanche 38 Débitmètre 7 Arrivée gaz 39 Limiteur de débit d'eau 8 Sortie eau chaude sanitaire 42 Capteur de température eau chaude sanitaire 9 Entrée eau chaude sanitaire...
  • Página 48 DIVAtech F 32 D 5.3 Tableau des caractéristiques techniques 5.4 Diagrammes Diagrammes pression - puissance Donnée Unité DIVAtech F 32 D Puissance thermique maxi 34.4 Puissance thermique mini 11.5 Puissance thermique maxi chauffage 32.0 Puissance thermique mini chauffage Puissance thermique maxi eau chaude sanitaire 32.0...
  • Página 49: Schéma Électrique

    DIVAtech F 32 D 5.5 Schéma électrique LC32 ABM01 ° ° ° 230V 50 Hz fig. 21 - Circuit électrique Attention : Avant de brancher le thermostat d'ambiance ou la chronocom- mande à distance, défaire le pontage sur le bornier.
  • Página 50: Panoul De Comand

    2.1 Prezentare fig. 2 - Oprirea centralei DIVAtech F 32 D este un generator termic pentru înc lzire i pentru prepararea apei cal- de menajere cu un randament ridicat, care func ioneaz cu gaz natural, dotat cu arz tor Când centrala este oprit , cartela electronic mai este înc alimentat cu energie electri-...
  • Página 51: Dispozi Ii Generale

    DIVAtech F 32 D Reglarea temperaturii ambientale (cu termostat ambiental op ional) Reglarea presiunii hidraulice din instala ie Stabili i cu ajutorul termostatului ambiental temperatura dorit în interiorul înc perilor. Presiunea de umplere a instala iei reci, indicat de hidrometrul centralei (det. 17 - fig. 1), Dac nu este prev zut cu termostat ambiental, centrala asigur men inerea instala iei trebuie s fie de aproximativ 1,0 bar.
  • Página 52: Racordurile Electrice

    DIVAtech F 32 D 3.5 Racordurile electrice M suri de precau ie Aparatul trebuie s fie racordat la o instala ie eficient de împ mântare, reali- zat în conformitate cu normele de siguran în vigoare. Solicita i personalului calificat profesional s verifice eficien a i compatibilitatea instala iei de îm- p mântare, produc torul nefiind responsabil pentru eventualele pagube cauza-...
  • Página 53 IMPORTANT - ÎNC PEREA TREBUIE S FIE DOTAT CU O AERISIRE ADECVAT Dac inten iona i s racorda i centrala DIVAtech F 32 D la un horn colectiv sau la un co de fum separat cu tiraj natural, hornul sau co ul de fum trebuie s fie proiectate în mod expres de personal tehnic calificat profesional, în conformitate cu normele în vigoare, i...
  • Página 54: Punerea În Func Iune

    DIVAtech F 32 D 4. EXPLOATAREA I ÎNTRE INEREA A - Priza de presiune din amonte 4.1 Regl rile B - Priza de presiune din aval Transformarea gazului de alimentare I - Conexiune electric valv gaz R - Ie ire gaz Aparatul poate func iona cu alimentare cu gaz metan sau G.P.L.
  • Página 55: Rezolvarea Problemelor

    DIVAtech F 32 D Anomalie Cauz posibil Solu ie anomalie Cablaj întrerupt Verifica i cablajul Anomalie valv gaz Verifica i i eventualînlocui i valva de Valv de gaz defect Verifica i ventilatorul i cablajul ventila- Anomalie ventilator torului Verifica i i eventualînlocui i dia-...
  • Página 56: Circuitul Hidraulic

    DIVAtech F 32 D 5. CARACTERISTICI I DATE TEHNICE 5.2 Circuitul hidraulic Tabel. 9 - Legend figuri cap. 5 5 Camer etan 38 Fluxostat 7 Intrare gaz 39 Limitator de debit ap 8 Ie ire ap cald menajer 42 Senzor temperatur ap menajer...
  • Página 57: Tabel Cu Datele Tehnice

    DIVAtech F 32 D 5.3 Tabel cu datele tehnice 5.4 Diagrame Diagrame presiune - putere Unitate DIVAtech F 32 D Putere termic max. 34.4 Putere termic min. 11.5 Putere termic max. înc lzire 32.0 Putere termic min. înc lzire Putere termic max. ap cald menajer 32.0...
  • Página 58: Schem Electric

    DIVAtech F 32 D 5.5 Schem electric LC32 ABM01 ° ° ° 230V 50 Hz fig. 21 - Circuitul electric Aten ie: Înainte de a racorda termostatul de camer sau cronocomanda la distan , scoate i puntea de pe panoul de borne.
  • Página 59 DIVAtech F 32 D Comfort . 11 - . 1) • . cap. 4.4) . 11 • . 1) “d3” “d4”. • • • • • • • " " ( . 7 - . 1) • • • . 2 - "...
  • Página 60 DIVAtech F 32 D . 17 - . 1), a F37. . 7, . 1. ECO/COMFORT COMFORT), ECO), eco/ comfort ( . 7 - . 1). . 12 - . 1). " " " "/" " ( . 7 - .
  • Página 61 DIVAtech F 32 D "Y" 3 A. “HAR H05 VV-F” 3x0,75 . 21. . 9 - . 2 - Ø126 Ø82 . 8 - "C", Ø60 Ø130 010006X0 010018X0 010007X0 Cny, . 10 - . 3 - 60/100 80/125 90°...
  • Página 62 DIVAtech F 32 D . 6 - 1KWMA38A 1KWMA83A 1KWMA06K 45° 1KWMA01K 45° 1KWMA65A 90° 1KWMA02K 90° 1KWMA82A 90° + 1KWMA70U . 11 - 1KWMA16U 1KWMA55U 1KWMA05K . 4 - 1KWMA85A 1KWMA86A 1KWMA84U 12,0 . 80/80 1KWMA83U + 1KWMA86U 80 - 100...
  • Página 63 DIVAtech F 32 D cap. 5, ~ 24Ω ~ 65Ω • • . 1 ( 2 - ) “b01“ • . 1 ( . 1 2 - ) 00 ( 01 ( • . 1 2 • . 16 - TYPE SGV100 .
  • Página 64 DIVAtech F 32 D . 17 - • • • • • . 1) "A") 180 . RESET ( . 6 - . 1) RESET “F”) cod. 3541A770 - 10/2011 (Rev. 00)
  • Página 65 DIVAtech F 32 D . 9 - cap. 5 . 19 - . 20 - . 18 - cod. 3541A770 - 10/2011 (Rev. 00)
  • Página 66 DIVAtech F 32 D DIVAtech F 32 D 34.4 11.5 32.0 32.0 Pmax (80-60°C) 93.1 91.0 92/42 EEC 3 (<150 mg/kWh) (NOx) n° x 15 x 1.35 GPL ( mbar 20.0 (G20) mbar 12.0 (G20) mbar H [m H 3.64 1.22...
  • Página 67 DIVAtech F 32 D LC32 ABM01 ° ° ° 230V 50 Hz . 21 - > cod. 3541A770 - 10/2011 (Rev. 00)
  • Página 68 DIVAtech F 32 D . 11 - . 1) ’ “d1”. Comfort ( Comfort ( ) ( i • . 11 - . 1) ’ • . cap. 4.4) ’ . 11 - • . 1) ) ’ “d3” “d4”.
  • Página 69 DIVAtech F 32 D . 17 - . 1), ’ F37. . 7, ECO/COMFORT ( - COMFORT) , ECO), eco/ comfort( . 7 - . 1). - ECO . 12 - . 1). COMFORT ( eco/ comfort ( . 7 - .
  • Página 70 DIVAtech F 32 D "Y" ’ i ( I I : i i . "HAR H05 VV-F" 3x0,75 i ’ . 21. . 9 - . 2 - . 8 - " C" Ø126 Ø82 Ø60 Ø130 010006X0 010018X0 010007X0 .
  • Página 71 DIVAtech F 32 D . 6 - 0,5 M/F 1KWMA38A 1 M/F 1KWMA83A 2 M/F 1KWMA06K 45° F/F 1KWMA01K 45° M/F 1KWMA65A 90° F/F 1KWMA02K 90° M/F 1KWMA82A 90° M/F + 1KWMA70U . 11 - 1KWMA16U 1KWMA55U 1KWMA05K . 4 -...
  • Página 72 DIVAtech F 32 D (G.P.L.), ~ 24Ω cap. 5, ~ 65Ω • • . 1) ’ "b01", • . 1), 00 ( 01 ( GPL, . 16 - • . 1) TYPE SGV100 • TEST . 1) . 15 - TEST.
  • Página 73 DIVAtech F 32 D . 17 - • • • F20, • i 10 • . 11 - . 1), 180 . "A"): RESET ( . 6 - . 1) RESET "F") cod. 3541A770 - 10/2011 (Rev. 00)
  • Página 74 DIVAtech F 32 D . 9 - cap. 5 i i ( . 19 - . 20 - . 18 - cod. 3541A770 - 10/2011 (Rev. 00)
  • Página 75 DIVAtech F 32 D DIVAtech F 32 D 34.4 11.5 32.0 32.0 i Pmax (80-60°C) 93.1 i 30% 91.0 92/42 EEC 3 (<150 mg/kWh) (NOx) n° x 15 x 1.35 GPL ( mbar 20.0 (G20) mbar 12.0 (G20) mbar H [m H 3.64...
  • Página 76 DIVAtech F 32 D LC32 ABM01 ° ° ° 230V 50 Hz . 21 - cod. 3541A770 - 10/2011 (Rev. 00)
  • Página 77: Dichiarazione Di Conformità

    Dichiarazione di conformità Il costruttore: FERROLI S.p.A. Indirizzo: Via Ritonda 78/a 37047 San Bonifacio VR dichiara che questo apparecchio è conforme alle seguenti direttive CEE: Direttiva Apparecchi a Gas 2009/142 • • Direttiva Rendimenti 92/42 Direttiva Bassa Tensione 2006/95 •...
  • Página 78: Déclaration De Conformité

    Déclaration de conformité Le constructeur : FERROLI S.p.A. Adresse: Via Ritonda 78/a 37047 San Bonifacio VR déclare que cet appareil est conforme aux directives CEE ci-dessous: Directives appareils à gaz 2009/142 • • Directive rendements 92/42 Directive basse tension 2006/95 •...
  • Página 80 FERROLI S.p.A. Via Ritonda 78/a 37047 San Bonifacio - Verona - ITALY www.ferroli.it...