Keep all safety instructions and instructions for future reference.
Care
Only clean the device when it is switched off and with the mains plug unplugged. Use a soft, lint-free cloth. This can be
slightly moistened if necessary. Avoid contact with electrical components and moisture. After cleaning, allow the device to
dry completely before putting it back into operation. Do not use aggressive cleaning agents.
Commissioning
Before commissioning, please check the correct installation of the protective screens again; there is a risk of injury if they
are not installed correctly. Generally, the device may only be operated when completely assembled. Make sure that the
connected supply cable is free of damage. Never operate a device with a defective supply cable. There is a risk of electric
shock. Position the device upright and stable. When positioning the fan, make sure that curtains or other objects do not
obstruct the air flow. Insert the power plug into a properly fused power socket.
Assembly
1. Oscillating Knob
2. Tilt Range Screw
3. Tilt Adjustment Knob
4. On / Off / Speed Knob
5. Stand Locking Knob
6. Height adjustable knob
7. Base Washer
8. Base Thumb Screw
9. Fan Head
10. Tilt Range Knob
11. Tilt Adjustment Bolt
12. Wooden Stand
13. Stand Holder
14. Base
15. Joint
a. Mount the stand to the base (14) by using base thumb screw (8) and base washer (7).
b. Ensure that the stand is set to medium height and the screw for height adjustment (6) is slightly tightened.
c. Take the fan head (9) unscrew the stand looking knob (5) and insert the bottom part of the fan head onto the stand (12).
Caution: Ensure that the joint (15) is adjusted in an upright position to prevent the fan head from pressing on the stand.
Otherwise scratches may occur! If necessary, straighten the joint (15) before continue. Position the fan head, so that the
hole of the stand (12) and the hole for the stand locking knob (5) are align. Fix the locking knob and fasten well.
Technical Information
Power Rating: 50 W
Service Value: 1,3 (m³/dak.)/W
Fan Sound Power Level: 53,8 // 56,6 // 65,4 dB(A)
Max. Fan Flow Rate: 64,91 m³/min
Stand By Power Consumption: 0 W
Max. Air Velocity: 3.0 // 3.7 // 4.3 m/s

Publicidad