SPECIFICATIONS

Model
Motor
Power Source
Output Power
Current
Tank Capacity
Maximum Pressure
at 40 PSI
(2.8 bar)
Free Air
at 90 PSI
Delivery
(6.2 bar)
at 100 PSI
(6.9 bar)
Lubrication

APPLICATIONS

Air source of the pneumatic nailer and stapler.

PRIOR TO OPERATION

1. Power source
Ensure that the power source to be utilized conforms
to the power source requirements specified on the
product nameplate.
2. Power switch
Ensure that the knob of the pressure switch is in the
"OFF" position. If the plug is connected to a
receptacle while the knob is in the "ON" position, the
compressor will start operating immediately and can
cause serious injury.
3. Extension cord
When the work area is far away from the power
source, use an extension cord of sufficient thickness
and rated capacity (refer page 6). The extension cord
should be kept as short as practicable.
WARNING:
Damaged cord must be replaced or
repaired.
4. Confirm the power receptacle
If the power receptacle only loosely accepts the plug,
the receptacle must be repaired. Contact the nearest
electric store for repair service.
If such a faulty receptacle is used, may cause
overheating, resulting in a serious hazard.
5. Air coupler installation
Screw in the air coupler to the joint (Refer to Fig. 1 and
Fig. 2). The screw size of the joint is 3/8". Use an air
coupler which has the same screw size.
EC10SB (S)
Single-Phase, Induction Motor
Single-Phase, 115V AC 60Hz
1.5 HP (1.1 KW)
15.0 A
3.3 gal. (12.5 ltr)
116 PSI (8.0 bar)
4.9 CFM (138 ltr/min)
3.5 CFM (98 ltr/min)
3.3 CFM (95 ltr/min)
Oilless

OPERATION

1. Start up
Insert the plug into the receptacle and start the
compressor by pulling the knob of the pressure switch
to "ON". (Refer to Fig. 1 and Fig. 2).
WARNING:
The operation of the compressor is automatic and is
controlled by the pressure switch which stops it when
the pressure in the air-tank reaches the maximum
level and restart it when the air pressure drops during
use to the restart level.
The motor of the compressor is fitted with a thermal
protection inside-the wrap, which stops the
compressor when the temperature is too high. Should
this be tripped, the compressor will restart automati-
cally after 15–20 minutes.
2. Adjustment of working pressure
Unlock the knob of the pressure reducer pulling it up,
adjust the pressure to the required level by turning the
knob clockwise to increase and counterclockwise to
decrease.
A pressure gauge is provided to know when the
required pressure is reached, lock the knob by
pushing it down firmly (Fig. 2).
When adjusting the pressure, check and make sure
that a pressure gauge for the tank has the pressure
level that is higher than that of the pressure to be
adjusted.
It is also imperative that you make adjustment by
slowly starting up the pressure from the level that is
lower than the pressure to be adjusted.
— 9 —
Do not stop or start the compressor
by use of the plug. Always use "ON/
OFF" knob located on the pressure
switch.