• When the device is turned on, the gas canister should
always be placed in the designated container sleeve.
• In order to prevent injury from sharp edges we recommend
wearing safety gloves during assembly.
• Only use the gas types and canisters recommended by the
manufacturer! (See Section IX page 9)
• Repairs and maintenance of gas-related parts are only to
be carried out by authorised specialists.
• In case of malfunction, the canister valve (B) should be
closed (see Fig 2 on page 22).
• The gas hose should be inspected for damage at least
once a month and each time the canister is changed.
• The gas hose should be inspected every five years by an
authorised specialist.
• If the gas hose is damaged, it must be replaced by a hose
of the same quality and length.
• In the event of a gas leakage, the device should not be
used. If it is in use, the gas supply must be blocked. Before
it is used again, the device must be thoroughly checked
and any damaged parts replaced. Any loose connections
must be tightened.
III. Connecting the device to the gas canister
The following parts are necessary to connect the appliance to the gas bottle:
-
commercial propane/butane gas – liquid gas canister (5 or 13 kg)
-
fixed-value pressure regulator (supplied),
1.5 kg/h, suitable for the gas canister, operating pressure 28-30/37 mbar
-
1.4 m hose (supplied)
-
approved leakage locating spray or foaming agent (e.g. Gas Control Spray or suds).
GB
Assembly instructions COSYSTAND PROFI • 01-01-2012
Ceiling
1 m
1 m
(Fig. 2 - page 22)
21