1- Return safety valve
2- Checking valve connection
3- Non-return valve
4- Pressure reduction valve
5- Closing valve
Putting into service:
Before connect hydraulically the water heater to water network lets the water flow some to time to remove
all dirty which could damage the safety valve and block the diffuser.
To fill the water heater properly leave a hot water tap open to drain the water heater tank and only close it
when water comes out fluently. When water become hot after the necessary time tight again all connections to
assure a correct water sealing.
If the water network pressure is higher than the nominal pressure of the water heater, it is compulsory to
install special valve to reduce the water inlet pressure between 2 and 3 bar.
4.- CONNECTION OF THE WATER HEATER TO THE ELECTRIC NETWORK.
Prior to the connection to the electric network the connection cable must be built in. For it the protection
plate must be removed from the water heater. The connection of water heater to the electric network must be
performed according to standards for electric installation. Because the water heater has no components which
would permanently separate it from the electric network, upon the cable connection between it and permanent
installation a switch must be installed which breaks both power supply poles having between the open contacts a
gap at least 3 mm wide.
The below drawing shows the electrical water heater diagram:
5.- ELECTRICAL CONNECTIONS STANDARDS.
The electrical installation must fulfil the international standards CEI 64-8. According to these standards,
electrical appliances must be installed following the below indications at bathrooms and WC:
1.- zone 0: Installation is totally forbidden at this area. It is also forbidden at zone 1 if it is a prefabricated shower
cabin.
2.- zones 1 and 2: IPX4 appliances with a wire which allows connections 1,2 m from shower vertical and with an
additional RCS switch.
3.- zone 3: IPX1 appliances allowed.
4.- The earth connection of the water heaters is compulsory.
Fig. – 4 APARICI - SIE electrical diagram.