Starting Instructions
1. Place the heater on a stable and level surface. Insure clearance to
combustibles are observed (see table on this page).
2. Turn thermostat counter-clockwise to lowest setting.
3. Plug the heater into a properly grounded outlet.
4. Depress the power switch into the on "I" position.
5. Turn thermostat knob up (clockwise) until desired temperature is reached.
6. The Heating element and fan will remain on until the temperature
setting is reached. The unit will cycle on and off as needed.
To Stop Heating
1. Rotate the thermostat knob to the lowest position.
2. Flip the power switch into the off "O" position.
3. Disconnect plug from power supply.
NOTE: This heater is equipped with an overheat limit switch which may cause the
heater to stop. This is indicated by a visual alarm when the power switch is in the
on position and the "fault" light comes on. (fig 1) Check and remove the cause of
the overheating before restarting. Preform steps 1 through 3 of the Stop Heating
procedure above. Once the unit is cool (may take up to 15 minutes) remove the
black cap near the handle base, using a flat head screw driver if necessary. Using
a non-metallic object, depress the reset switch inside the access hole. When the
heater is plugged back into power and turned on the "fault" light will dim and the
heater may be operated again. Replace the black cap into the access hole.
Maintenance
WARNING:
Never attempt to service the heater while the unit is hot, In use, or plugged in. Only
qualified service technicians should service these units.
• Throughly inspect the unit prior to use.
• Keep heater clean and free of dust and debris.
• The use of an air compressor can be used to blow out the case. Be sure to only
use moderate air pressure as to not damage any internal components.
• A soft dry cloth should be used for cleaning of outer shell and handle.
• The fan motor is sealed and does not need to be lubricated.
NEVER LEAVE HEATER UNATTENDER WHILE BURNING
Specifications
Model:
DXH165
Heat Output BTU/WATTS
5118/1500
Airflow (CFM)
120
Electrical Supply
120V/12.5A /60Hz
Power Cord (supplied)
3-14 AWG
Plug (supplied)
NEMA 5-15p
Min. Extension Cord
3-12 AWG
Operating Temperature
0
Dimensions: (L"xW"xH")
13"x9"x11"
Weight (lbs.)
14 lb.
Clearance to Combustibles
Outlet (Feet)
6 (1.8m)
Rear (Feet)
2 (.6m)
Tom (Feet)
2 (.6m)
Bottom
Non-combustible floor
ON/OFF
FAULT/LED
4
F - 80
F
°
°
THERMOSTAT
FIG. 1