Due to the fan's movement, certain fastenings may become loose. Check all fastenings twice per year at a
minimum in order to ensure that they are sufficiently tight. If necessary, they must be retightened.
If the power cord is damaged, it must be replaced by the manufacturer, its after-sales service or similar
qualified personnel in order to avoid any malfunction.
Replaceable receiver
Do not refill the water tank with tap water, use only distilled water.
Maximum capacity of the water tank: 650ml.
Do not throw away electrical products together with household waste. We ask you to recycle the packaging
at the collection points provided for this purpose. Contact local authorities or your provider for recycling
advice. Thank you for recycling at the collection points provided for this manual.
Note: The important warnings and instructions indicated in this manual are not guaranteed to cover all possible conditions
and situations that may occur. It must be understood that common sense, precaution, and care are factors that cannot be
included in all products. These factors can and must only be provided by the user who maintains and enjoys this fan.
Device technical spectifications
Nominal voltage and frequency
Protection category
Protection index
Word temperature
Maximun ceiling slope on which it can be installed
Weight
Nebulizer specifications
10
Power
Maximum tank capacity
Autonomy
Speed
Fan power (W)
Fan RPM
Fan airflow (m³/min)
Noise level (dB)
Service value SV ((m³ / min) / W)
Power consumption in standby mode (W)
Service value measurement standard
Preparing for installation
Note: The estimated installation time is 120 minutes. This product can only be installed by a certified electrician Carefully
separate the fan's parts, avoiding the use of cutters or blades that could scratch any part of it.
CIF A28763647
220-240V~AC 50/60Hz
1
2
4,2
9,8
94
126
46,6
59,2
30
35
11,1
6,04
+34 916774540
Calle Verano, 51 - Polígono Industrial Las Monjas -28850 Torrejón de Ardoz - Madrid (ESPAÑA)
Remote control
Syncing the receiver and the remote control for fan operation
If the receiver and transmitter of this fan are properly synchronized, the fan will work. During synchronization the receiver
recognizes the signal from the transmitter, this is called the learning process.
Make sure the fan is disconnected. This is essential for the synchronization process.
Unless the synchronization process has been successful, the fan will work partially or will not work. By default, all fans have
been preconfigured at the factory and should be functional once the installation is completed and the fan is turned on.
If the remote control does not work after installation or during use, synchronization can be performed as indicated below. Note
Clase I
in any case that there could be other reasons why your fan or remote control does not work:
IP20
Make sure all connections are correctly made.
-5
40ºC
Make sure that the remote control contains batteries.
↔
Make sure that all switches (main and isolation) are on.
0º
7,2kg
Instructions for synchronizing the receiver and the remote control
The control of this fan does not require synchronization with the recelver, the control is already factory-linked with its receiver;
Universal mode and Unit mode:
3,8W
- Unit Mode:
650ml
This type of synchronization allows you to control two or more nearby fans independently, each with its remote control.
Synchronization:
3600min
The control of this fan does not require synchronization with the receiver, the control is already factory-linked with its receiver
- Universal Mode:
3
4
5
This type of synchronization allows you to control one or more nearby fans with the same remote control.
15
23
38
Synchronization:
151
175
205
1.-Connect the power (wall switch) of the fan or fans that you want to control, and then just within the following
15 seconds, press the key
71
96,3 109,4
2.-A "beep" sound indicates that the connection has been executed and the equipment can function normally.
38
42
52
3.-Now, transmitter and receiver of the fan / s will have been synchronized. Turn off the fan / s current using the
4,7
4,1
2,8
switch or automatic and then turn it back on / s, this step is the one that closes the synchronization process.
It is not possible for a controller to forget a fan once it has been linked, if you want a fan to leave
<0,5
to obey a command, another one must be linked to "overwrite it".
EN 62879:2020
Remote control safety functions
Blocking protection
The remote receiver includes a function that automatically blocks motor operation, cutting current to the motor 30 seconds
after detecting an obstruction in front of the fan that prevents normal operation. When this happens, you must remove the
obstacles blocking the fan. Then, press the off button on the remote control to reset the receiver. Now you can continue to
use the fan normally.
Note: Unless you remove the obstruction blocking the fan, it will not operate correctly.
Overload prtection
If the fan's receiver detects that the motor is operating at greater than 80W (this indicates an overload), current to the motor
will be cut automatically, which will immediately stop the fan. To reset the receiver, press the off button on the remote control.
Note: If the receiver goes into protection mode again, this may indicate a motor defect. Contact the supplier immediately. The
duration of the warranty is indicated in the warranty document provided in this manual.
ATC: 916749481 - info@sulion.es / SAT : 916749483 - sat@sulion.es
FAN
Turn on / Turn off fan
ON/OFF
*
Turn on water nebulizer
*
Water nebulizer 20"ON 40"OFF
20"
1
Speed 1
Speed 2
2
Speed 3
3
4
Speed 4
Speed 5
5
F/R
Change sense or rotation
1H
Timer 1h
2H
Timer 2h
*
If the tank is empty when pressing the button, a led will
4H
Timer 4h
light up. To fill the tank, follow the instructions in the section
8H
Timer 8h
"Installing the ceiling fan"
LED indicator
of the remote control for 5 continuous seconds.
FAN
ON/OFF
11
www.sulion.es