trigger (M1), turn the winch handle counterclockwise (N2) to descend the load until the
first profile is at its bottom position (step 3).
SEE FIGURE 6.
Press the knob of profile #1 to fix it for transport. Release the knob of profile #2, free the
trigger (M2) and keep folding down the tower until this second profile is at its bottom
position. Press the knob of the profile #2 to fix it for transport. Release the knob of profile
#3, free the trigger (M3) and keep folding down the tower until this third profile is at its
bottom position. Press the knob of the profile #3 to fix it for transport. Release the knob
of profile #4, free the trigger (M4) and keep descending the load until the tower is
completely folded down to its minimal height.
Finally press the last knob that remains to avoid vibrations during transport.
Just like when lifting the load, the tower may be stopped in any desired intermediate
position.
4.8.- For transport it is necessary to fold down the tower by retracting its profiles
completely and fix them with the adjustment knobs. Dismount the legs by releasing the
retention triggers and place them in their transporting position (S). Press the fixing screws
(J).
SEE FIGURE 7.
5. Maintenance
5.1.- All cables must be checked regularly. Faulty cables need to be replaced
immediately. Do not use the lifting tower with faulty cables. It is dangerous.
Use only torsion-free steel cables according to DIN 3060 standard.
5.2.- The tower is delivered ex works completely greased. Depending on its mechanical
strain, however, it is recommended to grease the crown wheel of the winch, the pads
and bushings of the drive shaft, the thread of the handle and the profiles of the tower
periodically.
ATTENTION:
Do not apply oil or grease to the brake mechanism.
The brake discs have been pregreased with a special heat and pressure resistant
grease. To avoid malfunctions of the winch brake, no other products must be used
except the original provided by the company.
It is not necessary to grease the brake discs.
5.3.- The lifting tower T-106 must be inspected at least once a year by a specialized
technician.
5.4.- Only original spare parts must be used to ensure a consistent operational safety.
The user shall lose all warranty claims if he uses any other than original spare parts or
modifies the product in any way.
5.5.- In case a spare part is required, it is necessary to indicate its reference number
which can be found in the spare parts table in this manual.
SEE TABLE 1.