The checklist below may help you troubleshoot in the unlikely event that a problem occurs while using the product:
No response from unit.
Unit resets correctly but does not respond (or
does not respond correctly) to the controller.
Error after unit reset.
Light output cuts out intermittently.
No power to unit.
Internal fault.
The controller is not connected.
Bad DMX-line.
DMX-line has no end resistance.
Incorrect unit addressing.
A unit is defective and is disturbing data
transmission on the DMX-line.
Pin 2 and 3 are reversed in XLR connection.
Effect requires mechanical adjustment.
Unit too hot.
LEDs damaged
The power supply settings do not
match local AC voltage and
frequency.
Check that power is turned on.
Check cables and connections.
Contact Beamz support or Beamz authorized
service partner. Do not remove base or yoke
covers. Do not attempt to replace a fuse or
carry out any repairs or service that are not
described in this User Manual unless you have
both authorization from Beamz support or
Beamz authorized service partner.
Connect controller.
Inspect connections and cables. Correct poor
connections. Repair or replace damaged
cables.
Insert DMX terminator plug in DMX output
socket of last unit on DMX-line.
Check unit address and DMX mode settings.
Unplug DMX IN and OUT connectors and
connect them directly together to bypass one
unit at a time until normal operation is
regained. Have defective unit serviced by an
authorized technician.
Inspect connections and cables. Install a
phase-reversing cable between the units or
swap pin 2 and 3 in the unit, that behaves
erratically.
Check unit's software version and error
messages for more information. Contact
Beamz support or Beamz authorized service
partner.
Allow unit to cool. Reduce ambient
temperature. Ensure free airflow around unit.
Clean unit if necessary.
Disconnect unit and contact Beamz support or
Beamz authorized service partner.
Disconnect unit. Check settings and
correct if necessary.