COMPACT INTERCOM MONITOR WITH STANDARD HANDSET
Features:
-
What is the COMPACT INTERCOM MONITOR WITH STANDARD HANDSET ( MONITOR)?
It is a standard digital monitor that, besides being able to communicate with panels and switchboards; it can also perform voice
o
intercommunication with up to 6 other intercom devices (TELEPHONE/MONITOR) connected at the same bus.
-
"Enable/Disable" Self-Starting configuration Jumper (J1).
If the jumper of J1 is removed or it is in 1-2 position, the self-starting will be enabled. If it is in 2-3 position, it will be disabled. The self-
o
starting can also be disabled for the entire installation form the panel.
-
"MASTER/SLAVE" Configuration Jumper (J2).
There can only be a MASTER device sharing the same bus. The rest must be SLAVES. If the jumper of J1 is removed or it is in 2-3 position, the
o
device will be set as MASTER. If it is in 1-2 position, it will be SLAVE. The facility will not work at all if there isn't any MASTER device or even if
there is more than one device set as MASTER.
-
MONITOR ID for "Panel Calls".
The MONITOR always responds to calls made from the panels to the code 1 except if SWITCH-5 is ON. In this case, the MONITOR will
o
respond to calls made from panels to code 2.
-
INTERCOMMUNICATION ID (switches from 1 to 4 of Sw1 ).
It is possible to codify addresses from 1 to 6, using the first 4 switches of the SW2. In case an ID greater than 6 is codified, the system will
o
warn us with a continuous beep.
-
Options (switches from 5 to 8 of SW1).
Switch 5. As mentioned above, if it is activated (down), this device will respond to panel calls to code 2.
o
Switch 6. Only Intercom. If it is activated (down), this will be only an intercom device. It will not be able to communicate with neither panels
o
nor switchboards.
Switch 7. Only Reception. If it is activated (down), this device will not be able to initiate any intercom calls. It will only be able to respond to
o
them.
Switch 8. Priority device. If it is activated (down), this device will end any current conversation, setting the line free to perform any new call.
o
-
MULTITONE Configuration (Up to 7 different melodies).
Pressing C with the MONITOR hung up; we can select the desired ringtone.
o
-
RINGTONES VOLUME Configuration (2 levels).
Pressing B we can select the ringtones volume.
o
-
Setting The NUMBER OF RINGTONES and the ELECTRONIC CALL EXTENSION (0 to 4 ringtones)
See Table 1.
o
-
Setting AUXILIARY OUTPUT (1 second pulse or TOGGLE)
See Table 1.
o
-
ID=0: EVERY MONITOR CODIFY WITH ID=0, will always make a "General Call" with just one touch of the (KEY button) + pick the handset up.
-
CONVERSATION LENGTH : Minimum 90s. From here, the conversation can continue indefinitely, unless a third party wants to use the line, which will
cause both devices will go to its standby mode. This is indicated by a short tone in the speaker during the conversation.
-
CALLS CANNOT BE RECEIVED if the handset is picked up.
Intercom Functioning:
STANDBY:
·
Handset hung up and blue led ON.
o
Make a call:
·
Keep the handset hung up, and press the KEY button as many times as indicate the MONITOR/TELEPHONE number you want to call. Then,
o
pick the handset up. (i.e., Call nº3)
§
Press three times de KEY button with the handset hung up. Verify the blue led gives you three flashes every 6 seconds. If the
MONITOR/TELEPHONE nº3 exists, it will start to ring and the blue led will blink quickly.
§
When trying to call to codes greater than 6, the system will return to code 1 and, if the line is busy, we'll heard a beep in the
handset, and the blue led will return to its original blue light.
General Call. With the handset hung up, keep the KEY button pressed for 2s. The blue led will blink quickly and when lifting the handset up, a
o
call will be made to all the MONITOR/TELEPHONES that have the "General Call" enabled. A conversation will begin with the first
MONITOR/TELEPHONE that picks up.
If we have already pressed the KEY button and we want to return to the standby mode without performing a call, we can press the AUTO
o
button, or pick up and hang up quickly, or just wait 30s. The blue led should return to its original blue light.
Receive a call:
·
While the handset is hung up, the MONITOR can receive calls. It will start ringing for up to 30s and the blue led will flash quickly. We may
o
terminate the call pressing the AUTO button, or just lift the handset up to start the conversation. At this point, the blue led will flash slower
and we will have audio at least for 90s (see "CONVERSATION LENGTH" in features).