CONNECT MAX 2 KEYPADS IN THE
CARD - B -
(to connect in parallel).
to do programming procedure
connect only 1 KEYPAD in the card
- B -.
TURN OFF POWER SUPPLY BEFORE
YOU INSERT THE CARD
WIRED KEYPAD PROGRAMMING
- Remove cover - A - from control panel.
- Insert card - B - cod. ACG9447 in one of the free places.
- Turn on control panel power supply.
- Press and maintain pressed button - C -. You have 5 seconds to digit the code (min.
4 / max 9 numbers) and confirm pressing button A . You hear a "BEEP" to confirm the
record of the new code.
- Release button - C - .
- Repeat these steps for every new code to record.
- Close cover of the control panel - A -.
SIGNALS
no "BEEP"s = code to record.
1 "BEEP" = code recorded.
2 "BEEP" = if code is already present in the memory.
3 "BEEP" = after deletion of one code.
4 "BEEP" = during deleting procedure. Code not present in memory.
WIRED KEYPAD - CONNECTIONS AND PROGRAMMING
FOR SLIDER AUTOMATIC DOORS
channel A
ATTENTION:
ATTENTION:
code ACG9447
SIG
5 "BEEP" = memory full (max 125 codes).
10 "BEEP" = All codes deleted.
DELETING ONE CODE
Press and maintain pressed button - C - up to obtain a permanent "BEEP".
Digit the code to delete (3 "BEEP" follows to confirm deletion).
Release button - C -.
DELETE ALL CODES
Press and maintain pressed button - C - up to when permanent BEEEP stops. (10
"BEEP"s follow to confirm total deletion).
Release button - C -.
Wired Keypad has backlighted buttons.