5. Enter the NETWORK menu to set/change the IP address, the SUBNET MASK, the WEB SERVER Port
and the DEFAULT GATEWAY previously associated to the streamer (SIG7730). From the module, it is
possible to enable or disable the DHCP function (automatic assignment of the IP address from the net-
work). By default, this option is disabled.
WARNING: do not use the HTTP port already occupied by others software process running.
NOTE – For SIG7730 settings it will be necessary to login once by using Username and Password
by default setting.
After setting all the parameters, confirm them with the SAVE command. Reset an IP address belonging
to the same sub-network in the network card of the local PC that is used for programming.
Enter the INPUT menu for the settings relevant to the digital terrestrial multiplex selections (to
6
modify the settings for the first time, it is necessary for the user to carry out the authentica-
tion by entering by default).
NOTE: from this menu, all the parameters relevant to the selection of the digital terrestrial multiplex can be
set. In the same picture is present the Status of the Tuner (locked/unlocked) and furthermore BER, S/N,
and hierarchy modulation priority of tuned multiplex are displayed.
Username --> admin
Password --> fracarro
Username --> admin
Password --> fracarro