Control Panel
POWER: Use this button to turn on or turn off the
appliance.
MODE CONTROL: Use this button to select the
function of this unit: AUTO/HIGH/LOW or FAN. The
appliance will start with the AUTO-function until you
choose another function. The AUTO-Modus is ideal for
domestic environment humidity of 50-55% RH and for
saving electricity.
You can choose between HIGH or LOW. If you choose
the
"FAN"-function
the
dehumidification.
LAMP: Please press this button to activate or
deactivate the lamp. The indicator light colour will
change according to the humidity condition:
Red: high humidity, RH ≥80%
Green: comfortable 80%-60% RH
Orange: dry, RH<60%
Note: It can take about 2 minutes until the indicator will
change the colour.
OSCILLATION: Use this function, if you need to set the
position of the louvers. There are 3 different directions:
45°, 90° or swing mode between 45° and 90°. Press
the button for the swing mode. If you continue pressing
the button, the louvers will change to 45° or 90°. Do not
operate the unit if the self-opening louvers do not open
on power on.
UP/DOWN key: Press UP/DOWN key to select the desired humidity level. Default relative humidity is 55%. If you select
35%, the compressor will not stop until the water tank is full. The humidity level can be set within a range of 35% RH to
80% RH in 5% increments. The compressor will work until the desired humidity is measured. The FAN-modus will change
automatically and will move the air around the room ensuring the entire air in the room is processed.
TIMER:
Power-off function:
- Press the Timer-button, while the device is on.
- Use the "up" or "down" key to set the time period (0-24 hours)
Power-on function:
- Press the Timer-button, while the device is off.
- Use the "up" or "down" key to set the time period (0-24 hours)
DEFROST: The appliance will defrost automatically as programmed once the coil sensor detects temperature. The
indicator will light up at the same time. Once defrosting finishes, the appliance will recover to its previous running mode.
When the unit is in a room where the temperature is between 5°C and 12°C, the defrost mode enters every 30 minutes.
When the unit is in a room where the temperature is between 12°C and 20°C, the defrost mode enters every 45 minutes.
TANK-FULL INDICATOR: Red light will be on and the unit will beep when the tank is ready to be emptied or when the
tank is removed or not replaced in the proper position.
IONIZATION FUNCTION: Use the Ionization function, to refresh the air in the room. As soon as you press the "ION"-key,
the light will come on.
Display:
- When the unit is plugged in, it will indicate the room humidity level.
- When the humidity level is selected, it will indicate the set humidity.
- As soon as you activate the timer, the set time will be shown on the display for a few seconds and then the humidity
level in the room will appear on the display.
Note: If ambient humidity is lower than 20%, it will show "LO". If ambient humidity is higher than 90% it will show "HI".
Compressor: When the selected humidity is 2% lower than the user selected humidistat setting; the compressor will be
fan
will
work
without
Up-Key
Ionizer
Timer
Mode
Tank-full indicator
Operation Indicator
Power
Down Key
Lamp
Oscillation
Defrost indicator