FS-Curtis FCT02C48H2X-A1X1XX Manual De Instrucciones Y Lista De Piezas página 11

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

INSTALLATION INSTRUCTIONS (CONTINUED)
Lubrication
Before operating compressor,
ensure oil is filled to the center of
the sight gauge (See Figure 4).
Using any other type of oil may
shorten pump life and damage
valves.
Recommended Oil (2 Options)
FSC-1000A ISO-100 Premium Reciprocating
Compressor Lubricant
1 quart part number FSC-1000A-1
12 quart case part number FSC-1000A-12
For generic option use 10W30
Oil Capacity
Approximately 8.5 oz.
Remove cap from oil fill opening. Install breather (found
in parts bag with this manual). Check oil level. See
specification label on compressor pump for the proper
oil capacity and oil type. All lubricated compressor
pumps discharge some condensed water and oil with
the compressed air. Install appropriate water/oil removal
equipment and controls as necessary for the intended
application.
Do not use regular automotive oil. Additives in regular motor
oil can cause valve deposits and reduce pump life. For
maximum pump life, drain and replace oil after the first fifty
(50) hours of operation. Then perform oil changes every
three (3) months.
Oil Drain
Plug
Sight Gauge
Figure 4 - Lubrication
9
Oil FIll
Area
Full
Low