Fault Diagnosis

The load lowered slowly
Cause 1:
Control lever adjusted wrongly
Remedy:
Readjust the control lever
➔ Loosen the clamp screw (A)
➔ Adjust the lowering spindle (B) with a screwdriver (C)
➔ Fix the position with the clamp screw (A) (refer to Fig. 4)
Cause 2:
Defective drain valve
➔ Replace the drain valve
Cause 3:
The drain valve does not close or the valve seat leaks because of oil contamination
➔ Clean the valve
➔ Replace the oil (→ 7.7)
The lift table does not lift, the pump supplies no oil
Cause 1:
Air in the hydraulic system
Remedy:
Vent the pump
➔ Operate the drain valve [1] with the right hand and at the same time perform a few
➔ Vent the cylinders (→ 7.8)
Cause 2:
Lack of oil
Remedy:
Top up oil
➔ Vent the cylinders (→ 7.8)
Jerky lowering
Cause:
Air in the hydraulic system
Remedy:
Vent the cylinders (→ 7.8).