Problems And Solutions - Catalonia Aqua Spa Manual De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 24

PROBLEMS AND SOLUTIONS

• Adjust water pH between 7,2 and 7,6 (see Water maintenance).
• Add all required chemical products recommended in Water maintenance (Maintenance Manual)
• Select the required temperature (see Control Keyboard of the Spa). Remember that if the water
is cold, it may take 24 hours to reach a temperature of 38ºC.
• Before using the Spa, check the pH values once again in case they have changed with the
treatments indicated above.
7. PROBLEMS AND SOLUTIONS
Problems
Insufficient flow of filtered water.
The massage pump of the Jets does not
work.
Spa does not work.
The massage pump of the air Blower
does not work.
Water leaks out through the Venturi.
Limited airflow in the Jets.
Reduced airflow.
The water does not reach the required
temperature.
Note: In the section Diagnosis message of the control panel (User Manual), the diagnosis messages
to solve possible breakdowns are indicated.
22
Spa for private use - Operating instructions
Reasons
Filter is blocked by dirt.
The cable of the digital control panel is
disconnected from the board.
No electrical supply.
Differential is disconnected.
The cable of the digital control panel is
disconnected from the board.
No electrical supply
The pump has disconnected owing to
overheating.
Jets are closed.
Jets are not properly installed. The
outer trim of the jet turns a quarter
to open and close the water flow. If
this trim makes a complete turn, it is
not properly installed, and the jet will
have to be removed and then placed
correctly.
Venturis are closed.
Starter brushes of the motor are worn.
Probe is damaged.
Check programmed temperature.
Solutions
Wash the filter.
Connect the cable to the board.
Check that the pump is connected to
the electric control panel.
Connect the differential.
Connect the cable to the board.
Check that the pump is connected to
the electric control panel.
Let it cool for about 3 hours and then
start-up the pump again.
Open the jet.
Remove the jet. Pull the outer trim
about 2 cm. Unscrew the jet turning
anti-clockwise. Once it has been
dismantled, replace the jet, by screwing
in a clockwise direction. Press the outer
trim back into place.
Open the Venturis.
Change the pump.
Replace the temperature probe.
Programme the temperature.

Publicidad

Tabla de contenido
loading

Tabla de contenido