The adjustable length consist of the upper part (with the standard locking band), the lower part (with the central
EN
locking band) and the additional insulation. Next steps are necessary to obtain the length required.
ATTENTION: Anti-cut gloves must be used to minimize risk.
Cut the additional insulation with a knife to the appropriate length (effective length required - minimum length) and
insert
it
into
the
upper
If the installation includes seals (for positive pressure), place the seal on the corresponding site and lubricate the
seal with soap.
Connect the two parts of the adjustable as shown in step 3. Fix the central locking band over the center of the two
parts of the adjustable.
Once the adjustable length is fitted, this product is assembled just like the rest of the pieces.
Step 1

Ampliaciones y Reducciones / Increasers and Reductions

10
Estos componentes se utilizan para realizar cambios de sección en la chimenea. Se tratará de ampliaciones
ES
cuando se aumente el diámetro en el sentido de los humos y de reducciones cuando se disminuya el diámetro en
el sentido de los humos. Se muestran ambas piezas a continuación en su posición de montaje.
These components are used to make changes in the section of the chimney. We talk about increasers when it
EN
change de diameter to a bigger one (following the flue gas direction), in the opposite we talk about reductions. Both
components are shown in the mounting position.
Ampliación / Increaser
2020-02
Instrucciones de montaje - Installation instructions
part
of
the
adjustable
as
shown
in
the
figure
Step 2
Reducción / Reduction
AVANT KA-KC-KI
of
step
2.
Step 3
8/11
8/1