Descargar Imprimir esta página

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

®
u INSTALLATION INSTRUCTIONS u
See inside for detailed illustrations and stress engineering report summary
WARNING! u NEVER USE NAILS OR UNSPECIFIED FASTENERS
to Anchor the Safety Boot - Different Types of Subfloor Material Require Different
Types of Fasteners In Order to Exceed the 200 lb. OSHA Guardrail Requirement
u IMPORTANT NOTICE u
All specifications and dimensions for building compliant railing systems given within these installation instructions are written to meet United States Federal OSHA requirements of
1926.502(b)(3), (4), and (5) which are subject to change. Individual U.S. States with their own State run OSHA agencies might have slightly different and varying specifications for
guardrail requirements. Be sure to check and confirm if your particular state follows Federal OSHA or State OSHA regulations. Always follow the specific safety regulations for your state
or region. This system is designed and tested for flat surface applications only.
MAKE SURE EACH PERSON READS AND UNDERSTANDS THESE INSTRUCTIONS PRIOR TO USE. FAILURE TO OBSERVE THIS WARNING COULD RESULT IN SERIOUS INJURY OR DEATH.
MANUFACTURER ASSUMES NO LIABILITY IN THE EVENT OF IMPROPER INSTALLATION, PRODUCT MISUSE, OR FAILURE OF WOOD CONSTRUCTION SUBSTRATE. NEVER ALTER OR MODIFY
THE SAFETY BOOT. ALWAYS CAREFULLY INSPECT EACH SAFETY BOOT BEFORE EVERY NEW INSTALLATION. REPLACE IMMEDIATELY IF YOU NOTICE ANY SIGNS OF EXCESSIVE WEAR, DAMAGE,
ABUSE OR PLASTIC DEGRADATION.
OSHA REGULATIONS (STANDARDS - 29 CFR)
Guardrail Systems - Non-Mandatory Guidelines for Complying with 1926.502(b) -
1926 Subpart M App B states that for wood railings:
. . . (1) For wood railings: Wood components shall be minimum 1500 lb-ft/in(2) fiber (stress grade) construction grade lumber; the posts shall be at least
2-inch by 4-inch (5 cm x 10 cm) lumber spaced not more than 8 feet (2.4 m) apart on centers; the top rail shall be at least 2-inch by 4-inch (5 cm x 10
cm) lumber, the intermediate rail shall be at least 1-inch by 6-inch (2.5 cm x 15 cm) lumber. All lumber dimensions are nominal sizes as provided by the
American Softwood Lumber Standards, dated January 1970 . . .
For Technical Support or to Reorder,
Call Toll Free 1.800.804.4741
www.safetyboot.com
FREE!
Drill Adapter(s)
Included With
© 201 SAFETY MAKER, INC.
All Orders!
P.O. Box 880
Cypress, Texas 77410.0880
u
Phone 832.593.0400 or 800.804.4741
Fax 832.593.0910 or 800.914.8019
u
Use the Supplied Drill Adapter with a Power Drill and Socket for Fast and Easy Installation

Publicidad

loading

Resumen de contenidos para SAFETY MAKER Safety Boot Guardrail System

  • Página 1 For Technical Support or to Reorder, Call Toll Free 1.800.804.4741 www.safetyboot.com FREE! Drill Adapter(s) Included With © 201 SAFETY MAKER, INC. All Orders! P.O. Box 880 Cypress, Texas 77410.0880 Phone 832.593.0400 or 800.804.4741 Fax 832.593.0910 or 800.914.8019 Use the Supplied Drill Adapter with a Power Drill and Socket for Fast and Easy Installation...
  • Página 2 ® u FASTENER SPECIFICATIONS u WARNING! u NEVER USE NAILS OR UNSPECIFIED FASTENERS to Anchor the Safety Boot - Different Types of Subfloor Material Require Different Types of Fasteners In Order to Exceed the 200 lb. OSHA Guardrail Requirement FASTENER SPECIFICATIONS FOR VARIOUS TYPES OF SUBFLOOR MATERIAL APPLICATIONS SOLID 2X WOOD APPLICATIONS STURD-I-FLOOR INCH THICK) PLYWOOD...
  • Página 3 ® u ADDITIONAL INFORMATION u u SAFETY BOOT GUARDRAIL SYSTEM u enable the builder to easily construct freestanding guardrail and stair rail systems that meet OSHA Standards on every job-site, even when using different employees or subcontractors. OSHA STANDARDS REQUIRE THAT ENGINEERING TEST DATA CERTIFICATION MUST BE AVAILABLE for the OSHA Compliance Officer...
  • Página 4 u STEP ONE u u STEP TWO u Assemble Posts Placement of Posts Assemble Guardrails Using (Stress Grade) Placement of Posts Should be Along Construction Grade Lumber Unprotected Sides or Edges Cut 2X4 lumber into two 42 inch lengths. Place Safety Boot Posts in line along all edges of DO NOT use wet or oversized lumber.
  • Página 5 Applies to Unprotected Sides or Edges - Subpart M— §1926.502 Fall Protection Systems Criteria and Practices NOTE Ï Extend the top rails and midrails past the terminal posts Leave Ample Room and stop the rails four (4) inches from the permanent structures to prevent an unprotected opening.
  • Página 6 A VARIETY OF INDUSTRIES. ONE OF THE SERVICES PROVIDED BY SES IS A TEST FACILITY IN WHICH A VARIETY OF PRODUCTS ARE TESTED. A SERIES OF TESTS WERE PERFORMED FOR SAFETY MAKER ON THEIR SAFETY BOOT . THE PURPOSE ®...
  • Página 7 SUMMARY OF SELECTED SAFETY BOOT STRESS TESTS PERFORMED BY SES ® TEST NO. & TEMPERATURE LAG BOLT FENDER WASHER SUBFLOOR MATERIAL MAX. FORCE POUNDS 1 : Room 3/8” x 3” 3/8” x 1-1/4” 23/32” STURD-I-FLOOR Plywood & 2” x 10” Yellow Pine 2 : Room 3/8”...
  • Página 8 Para Apoyo Técnico o Para Volver a Pedir, Llame Gratuitamente al 800.804.4741 www.safetyboot.com FREE! Taladro Adapter(s) Incluido con Todos los © 201 SAFETY MAKER, INC. Pedidos! P.O. Box 880 Cypress, Texas 77410.0880 Teléfono 832.593.0400 or 800.804.4741 Fax 832.593.0910 or 800.914.8019...
  • Página 9 ® u ESPECIFICACIONES DE SUJETADORES u ¡ADVERTENCIA! u NUNCA USAR CLAVOS O SUJETADORES NO ESPECIFICADOS para anclar la Safety Boot (Cubierta de Seguridad) – Tipos diferentes de material de contrapiso requieren tipos diferentes de sujetadores para cumplir con el requisito de OSHA de 200 lb. de resistencia de la baranda ESPECIFICACIONES DE SUJETADORES PARA VARIOS TIPOS DE APLICACIONES EN MATERIAL DE CONTRAPISO MADERA CONTRACHAPADA STURD-I-FLOOR APLICACIONES PARA MADERA MACIZA 2X...
  • Página 10 Para Apoyo Técnico o Para Volver a Pedir, Llame Gratuitamente al 800.804.4741 www.safetyboot.com © 201 SAFETY MAKER, INC. P.O. Box 880 Cypress, Texas 77410.0880 Teléfono 832.593.0400 or 800.804.4741 Fax 832.593.0910 or 800.914.8019...
  • Página 11: Montaje De Postes

    u PASO UNO u u PASO DOS u Montaje de Postes Colocación de Postes Instale los postes utilizando pies La colocación de los postes debe ser a lo derechos de 2 x 4 largo del lado o borde sin protección Corte un pie derecho de 2 x 4 en dos tramos de Coloque los postes de la Cubierta de Seguridad alineándolos a NO USE...
  • Página 12 Se Aplica a los Lados y Bordes Sin Protección – Subparte M – § 1926.502 Criterios y Prácticas de los Sistemas de Protección para las Caídas NOTA Ï Deje espacio para la instalación del muro de mampostería Se Aplica a Escaleras, Pasamanos, Sistema de Pasamanos de Escalera y Descansos de Escalera – Subparte X – Escaleras y Escalas NOTA los Estados 1926.1052(c)(7): cuando el borde superior...

Este manual también es adecuado para: