Overview
1
Transformer and Power Switch: 3 positions: Power on low
(position I), Power off (center position) and power on high (position II).
Top Cap: Remove this cap (snap fit) to change the Primary Filter or
2
to add #XF200 Primary Filter Expansion Kit(s), available separately.
3
Primary Filter: Activated carbon filter (Replacement # XF102)
4
Power Inlet Jack: Plug in transformer cord here.
5
Mounting Hole: 1/4"x20 threaded hole allows for mounting unit on a
tripod, etc. Max screw length 5mm.
Pre-filter: Activated carbon fiber pad (Replacement # XF105)
6
7
Hood: Removable. Can be attached in any position.
8
Hood Grip: Soft rubber, removable.
Basic Operation
Connect the Transformer cord to the Power Inlet Jack
on the main housing. Plug the Tranformer into a power
outlet. The Power Switch has two positions marked "I"
and "II". Switch position I provides quieter operation
and lower air flow for more efficient smoke removal.
Switch position "II" provides higher air flow. Use the
setting that best suits your needs.
The unit should be placed close to the source of
smoke for best results. We recommend using it with
the Hood attached, but it can be used without the
Hood if desired. Because the Hood is square it will
snap into the housing in any position, The unit can be
used upright or laying on its side (see front page). It
is generally most effective at capturing smoke in the
upright position. The Hood can be used with or without
the supplied Hood Grip.
The Razaire™ MINI can be left running for extended
periods in order to further reduce smoke particles from
the air.
Cleaning
If desired the main body of the unit and the Top Cap
can be cleaned with a damp cloth. The Hood and Hood
Grip can be cleaned in soapy water and dried with a
soft cloth. Do not use cleaning chemicals on the Hood.
Use care to avoid scratching the Hood when cleaning.
Do not attempt to wash or otherwise clean the filters.
Technical Data
Model: Razaire™ MINI X60
Operating Power requirements: 12DC 1.0A
Power Transformer Input: 120-240VAC, 50/60Hz, 0.50A
Output: 12VDC, 1.0A
Operating temperature range: 13C to 40C
Size: 5.25"x5"x6" (133mm x 127mm x 153mm)
Weight: 0.95 lb / 430gm
For most effective smoke reduction the filters must be replaced regularly. Recommended
replacement interval for the Pre-filter is approximately every 25 hours of burning if you burn hot
and generate lots of smoke, and approximately every 50 hours if you burn more moderately. The
Primary Filter should be replaced every other time you replace the Pre-filter. This works out to
roughly 50-100 hours between Primary Filter changes. This is a basic guidline only. You may find
that you want (or need) to replace filters more frequently or less frequently, depending on how
effective you feel the filter is removing smoke while you're burning. The unit can still be used
as a fan to draw air away from your burning surface even if the filters are removed or no longer
effective. Replacement filters are available from your dealer or directly from Razertip.
Replacing the Pre-filter
6
The Pre-filter
is held in by friction and simply pulls out of the unit. Install a new filter by pressing
it into place. This can be done with the Hood either attached or removed. Dispose of old filter with
household trash.
1
5
4
6
5
Your Razaire™ MINI is guaranteed to operate properly for a period of three (3) years. This warranty does not cover filters as they are a
consumable item. Filters are guaranteed to be free from defects at time of purchase. The warranty provides for repair or replacement, at the
manufacturer's option, of any defective components. This warranty is limited to the actual cost of repairs and will not cover shipping costs or
any consequential damages resulting from failure of the unit or its components to perform as stated. All warranty work must be done by the
manufacturer. The manufacturer will not cover the costs of repairs done elsewhere.
Warranty will be voided if the unit has been tampered with, altered or repaired by unauthorized persons or companies. In the event that your
unit should need service, our average repair turn around time is only one day in shop. To receive in-warranty or out-of-warranty servicing,
return the complete unit to your dealer or send it directly (prepaid) to Razertip Industries Inc.
Filter Replacement
Replacing the Primary Filter
Pry the Top Cap
body of the unit. The Primary
3
Filter
unit. Drop the new filter in place
(any position will work). Snap the
Top Cap back in place. Old filters
are compostable (with paper
frame removed), or they can
be disposed of with household
trash.
You can increase the filtering
efficiency of the Razaire™ MINI by
2
adding one or more Primary Filter
Expansion Kits (#XF200). Each kit
includes an Expansion Frame and a
new Primary Filter. To install simply
remove the Top Cap from the unit
and snap in the Expansion Frame.
The extra filter can be set directly on
top of the existing filter (be sure to
remove the protective paper sides
from the new filter first). Snap the
Top Cap back in place.
4
You can add as many extra Primary
Filter stages as you want, however
air flow through the unit will be
reduced slightly with each additional
filter stage you add.
Note: You cannot add extra Pre-
7
8
filters to the Razaire™ MINI.
Warranty Information
2
from the
3
simply lifts out of the
Adding Primary Filter Stages