MAINTENANCE AND DISASSEMBLY
ALWAYS disconnect power before performing maintenance. Pump and
deck may be removed from tank by pushing tabs located on tank sides
away from deck while lifting on pump cover.
Periodically inspect the condensate pump tank to ensure it is free of accu-
mulated dirt or sludge. DO NOT use solvent cleaners. Clean tank with soap
and warm water only. For pump service/
replacement, entire check valve/shuttle assembly can be removed via 1/4-
turn engagement.
Rotate tab 1/4-turn to
and pull
up. This will prevent all water still
A
remaining in tubing from draining
out. However, the check valve may
be removed for cleaning or
replacement by first unlocking and
removing the check valve shuttle
assembly and then unscrewing the
2
barbed fitting with a 5/8" wrench.
This is required to remove the check
valve from the shuttle body
(for service/replacement).
Clean inlet and outlet piping. Re-
assemble system and check for
correct operation.
C O N D E N S AT E M A N A G E M E N T
1 2