3. Use the clamp meter to clamp the current test end of the splitter
to obtain the current reading.
Select different test terminals according to different current.
Select "X1" to get the normal load current; select "X10" to increase
the current readout by 10 times to increase the current
resolution.
The presence of the clamp meter itself will affect the accuracy
of the test, so please select the high precision clamp meter.
6.2 Voltage Test
1. Plug the load plug into the splitter socket.
2. Plug the splitter into the power outlet.
3. Make the function rotary of the multimeter to AC 600V, insert the
probe into the sockets of the live wire and neutral wire to read
the operating voltage of the load.
6.3 Power Test
1. Plug the load plug into the splitter socket.
2. Make the function rotary of the multimeter to AC 600V, insert the
probe into the sockets of the live wire and neutral wire.
3. Plug the splitter into the power outlet.
4. Select the appropriate current test on the splitter with a clamp.
5. Take the readings of the clamp meter and multimeter separately,
power can be calculated by the following formula: P = U * I.
All manuals and user guides at all-guides.com
- 05 -