The JMP2 jumper selects the control of green LED:
Inside:
The green LED visualizes the state of "output"relay.
The red LED is controllable trought a positive tension of 13,5V cc on the "R"pin of the
terminal box.
External:
The green LED is controllable trought a positive tension of 13,5V cc on the "V"pin of the
terminal box.
The red LED is controllable trought a positive tension of 13,5V cc on the "R"pin of the
terminal box.
This condition is available if SK100 is linked to the TM series anti-burglar control unit; two
control input (V-R) of the LEDs must be linked to the terminal V and R on the control-unit, so
green LED on,indicates that the control unit is disconnected, off means that the control unit is
connected; the on red LED indicates possible open zones. Two LEDs that flash
simoultaneously indicate the output time of the control unit.
JMP2
LED ON
on "Int."
GREEN
LED
RED
LED
GREEN
AND RED
LED
In each case SK100 card has the priority on visualization, that will stop two input lines to
visualize its own functions when necessary, for example in programming phase or after having
recognize a false key; in this case, two LEDs flash simoultaneously for 5 seconds, and the output
relay "False Key"is active.
CODING OF KEYS
Coding of keys with the code saved on the card:
Enter in programming by pressing programming key on the card for 4 seconds. Exsternal
control of LEDs will be stopped and green LED will flash.
Inserting a key, green LED will stop for some instants to indicate that have reconignized the
presence of a key in the connector ; if it will glow fixed, the key will be coded with the new code
present in the memory of the card; if it will fash, the key will not have been coded because
broken or badly inserted in the connector.Removing the key the red LED will flash again and it
JMP2 = Int.
JMP2 = Est.
LED OFF
Relay
Relay
ON
OFF
Controlable with
8 position on the clip
JMP2
LAMP.
on "Est."
GREEN
LED
RED
LED
GREEN
Insertion
AND RED
false key
LED
ON
OFF
Central unit
Central unit
switched off
switched on
Closed zones
Open zones
Open
Closed
zone/s
zone/s
SK100
LAMP
Centrale unit
swithched off
Esclused zones
Output
time