Installation:
The spotlight must shine in the opposite direction to the house or terrace to avoid the lighting
being too harsh.
The spotlight must be positioned 60cm maximum under the rim of the pool, measured from
the axis of the bulb. The spotlight recess is supplied with two 3/4" outputs. The rear output is
generally used for brick-built pools and the vertical output for panel-built pools.
Brick and liner structure
• Install the construction protection on the front of the recess.
• Seal the spotlight recess in the brickwork. Finish the plaster flush with the front surface,
making sure the recess is orientated upwards. Block the unused outlet using the plug.
• Install the seal on the front of the spotlight recess.
• Install the seal on the spotlight recess flange.
• Attach the sealing flange after the liner has been installed.
• Cut the liner
Panel and liner structure
• Use the template to drill the panel
• Install the spotlight recess from inside the pool. Screw it onto the panel after installing the
foam, placing the spotlight unit fastening grooves in a horizontal position.
• Seal the liner, the sheath and the cable and install the spotlight unit in the same way as the
liner spotlight.
Brick structure without liner
• Seal the spotlight recess into the brickwork, with the front part set back to allow the finishing
plaster or tiling to be installed.
• Seal the liner, the sheath and the cable and install the spotlight unit in the same way as the
liner spotlight.
Installing the spotlight
• Pass the spotlight unit cable through the cable gland. Ensure the cable gland fitting is correctly
positioned.
• Push the spotlight unit cable through the sheath to the terminal box.
• Seal the cable with the cable gland. Ensure the cable gland fitting is in the correct position.
(the 30° end is positioned in the bottom of the cable gland body).
• Hold the spotlight in front of the recess, winding the extra cable into it.
• Fit the spotlight into the recess, placing the prongs into the grooves.
Transformer power
The transformer to be used must have a secondary voltage of 12V (12.5V depending on the
model). The power must be suitable for the power of the spotlight(s) to be connected.
In all cases, the total power of the spotlights must be less than or equal to the power of the
transformer.
Each spotlight requires individual protection. Protection must be provided for the transformer
secondary winding using 5A or 6A fuses or circuit breakers (see wiring diagram below).
7