PERCENTUALIZZATORE Gp953 OUT 0-10vdc - pwm / ssr - relay
opera on:
At power turn on the equipment in sequence the various segments
the display to see if they are all func oning.
A er indica ng the percentage of igni on on a scale from 1 to 100.
red LED flashes in propor on to the outputs
pwm and relays, always lit with 0-10Vdc output
Start- stop
Press the start / stop bu on for 2 "in case of blackouts returns automa cally
the percentage that was providing.
Connec ons rear connector.
Pin 1: 240V ac input
Pin 2: 240V ac input
Pin 3: Relay output 1 pin
Pin 4: Relay output pin 2
Pin 5: Analog output 0-10V
Pin 6: logic output 18V / 50mA
Pin 7: + 24V dc (reverse protec on)
Pin 8: GND
G3Power.it
W.GSEI.IT
Programmation
To access the programming procedure must set the percentage
5amp 240vac
Power on the number 33 and hold the bu on for about 7 seconds
10amp 130vac
START / STOP un l you see the le er A appear on the display.
In the programming phase, you may vary the following parameters:
A: Opera ng period (range from 0.2 seconds to 999 seconds)
4
3
6
5
b: 1: Relay minimum 5 "Max 999"
2: Logic 18V / 50mAmp (SSR -PWM)
3: Analog 0-10V
C: Maximum percentage of power set
d: percentage of power Minimum se able
E: Number to be set to enter new password programming.
7
8
1
2
u liza on with 0-10Vdc output remove the nega ve ground connec ons.
L1 N
230vac
Dimensioni
48x48x100+ octal
www.g3power.it
w.gsei.it
led out