OPERATING PRINCIPLES :

Note : flexible hoses Ø38mm are not included in the By-pass kit.
In order to install your heat pump, it is necessary to create a « by-pass » on your filtration installa-
tion. It is a derivation on the filtration tube. The by-pass kit allows water to go through the heat pump
and adjust the water flow that circulates in it.
BY-PASS KIT ASSEMBLY ON A FLEXIBLE HOSE Ø38MM :
Note: During assembly, two mountains are possible
- Use teflon on the threaded fittings and screw the Ø 32 /
38mm adapters to the 3-way valve.
- Use the stainless steel inox clamps to tighten the hoses
on the adaptors.
3-WAY VALVE OPERATION :
Choice of 1 or 2
1
Position n ° 1: Closed
CAUTION: In this position, do not operate the
pump, which would be damaged by the fact
that it cannot deliver.
Position n ° 2: Open
Position n ° 3: 100% to the heat pump
Position n ° 4: 100% towards the swimming
pool
Position n ° 5: filtration flow reduced by 20%
Collier inox
2
Position n ° 1: 100% towards the heat pump
Position n ° 2: Open
Position n ° 3: Closed
CAUTION: In this position, do not operate the
pump, which would be damaged by the fact that it
cannot deliver.
Position n ° 4: 100% towards the swimming pool
Position n ° 5: 80% heat pump - 20% swimming
pool
Téflon