Fresh F100 T
Fresh F100 TH
FOR CLEANING AND MAINTENANCE: DISCONNECT THE POWER TO THE FAN.
1.
At regular intervals (every three months) the fan should be inspected and cleaned
to ensure that dirt or other deposits do not form.
2.
Wipe the inlet and front with a damp cloth until clean.
The fan has sealed bearings that do not require lubrication.
Figure 8
5min
30min
Figure 9
Overrun timer function (JP1).
JP1 to deactivate the timer, remove the jumper.
15 min. timer = jumper in place.
No timer = remove jumper.
Moisture adjustment
To increase START POINT:
Turn the potentiometer clockwise.
This makes the automation LESS sensitive.
To reduce SETUP POINT:
Turn the potentiometer counterclockwise.
This makes the controller MORE sensitive.
Start point adjustment for
moisture.
Speed selection (JP2).
The fan is factory set at low speed
(JP2)
with jumper JP2 fitted.
(JP1)
To activate high speed setting
remove jumper JP2.
17