23 electrolux how to use
Activate heating and cooling
This unit will not dispense hot or cold
water until the switchers are activated.
To activate, push top side of power
switches in to start heating and
cooling water:
• If you do not want to heat water,
push bottom side of red switch in.
• If you do not want to cool water,
push bottom side of green switch
in.
Dispensing water
This unit has been tested and
sanitized prior to packing and
shipping. During transit dust and
odors can accumulate in the tank and
lines. Dispense and dispose at least
one quart of water prior to drinking
any water.
Hot water
To get the hot water: slide the child
safety switch to right, and press hot
water button simultaneously.
Normal water
To get the room temperature water:
put the cup on the water collector grid
and press the natural water button.
Cold water
To obtain chilled water put the cup on
the water collector grid and press the
cold water button.
Cold water
Hot water
switch (red)
switch (green)
Child safety switch
C O L D
A L
N O R M
H O T
Warning
Never press more than one button at
the same time.
cold
hot
normal
water
water
water
outlet
outlet
outlet
Light indicators
The indicator lights show that the
device is working correctly. After
connecting the device, check if the
indicators are on.
Indicates when the bottle is
empty.
Indicates that the water in the
reservoir is being heated.
Indicates that water in the
reservoir is being chilled.
Warning
• When the machine is under the ice
point and blocked by ice, the
cooling switch must be closed for 4
hours before turning it on again to
continue its operation.
• This machine should not be turned
on until 3 minutes later after turning
off the power switch.
• Do not operate or stop the
appliance plugged in by the power
cord or by pulling on the power
cord. Unplug the power cord by
holding it by the plug.
• Do not operate or stop the
appliance plugged in by the power
cord or by pulling on the power
cord. Unplug the power cord by
holding it by the plug.
how to use electrolux 24
Changing bottles
The indicator (
) lights up when the
bottle is empty. Replace the bottle as
soon as possible.
Do not dispense hot, cool or cold
water if the red light is flashing as you
could empty the tanks and cause the
dispenser to overheat.
1. Open the dispenser door.
2. Slide empty bottle out of cabinet.
3. Remove probe assembly from
empty bottle. Place probe
assembly on probe hanger.
4. Set empty bottle aside.
5. Place fresh bottle outside of
cabinet. Remove entire plastic cap
from top of bottle. Clean outside of
new bottle with a cloth.
6. Place probe into bottle. Slide collar
down until it clicks in place. Push
head down until tubes hit bottom of
bottle.
7. Slide bottle into cabinet and close
door.