This is not an overload protection, but a personal protection switch.
In the event of an electrical leak, the device automatically shuts off the power supply and pre-
vents electricity from entering the human body.
The device should be connected directly to a power outlet.
Power supply via an extension cable is not recommended.
Technical data PRCD plug
Voltage / frequency
Rated current
Trip leakage current
Trip time
Degree of protection
5.4 Operation
Before starting the heat pump, the filter pump must be checked for correct operation.
The heat pump must never be operated without a pump.
Heating:
•
Press
to switch on the device
•
Use
and
to set the desired temperature
Now the device heats up to the desired temperature and then switches off automatically.
If the temperature of the incoming water is lower than the set temperature (-1 °C), the heat pump switches to
heating mode. The compressor stops if the temperature of the incoming water is higher than the set temper-
ature.
Under normal conditions, a suitable heat pump can warm the water in a swimming pool by 1°C to
2°C per day. It is therefore normal not to feel any temperature difference in the system when the
heat pump is in operation.
A heated swimming pool should be covered to avoid any heat loss and thus be more efficient.
Querying of parameters:
•
Press
until the settings menu appears
•
Use
and
to see the parameters
•
Press
to switch to the main screen
220 - 250 V~ / 50 - 60 Hz
10 A / 16 A
10 mA / 30 mA
< 0.1 s
IP54
1. Current LED
2. Defrost LED
3. Button: ON/OFF
4. Button: Select
5. Button: Up (+)
6. Button: Down (-)