The RISCO 16 Zone Expander enables to expand the number of wired zones in the ProSYS Plus.
DIP Switches Settings
Switch 1-5
Defines the Zone
Expander ID
number.
Switch 6-7
Not Applicable
Switch 8:
Instead of a short
Tamper Bypass
between the
TMP/COM
terminal block)
Zone Termination
Note:
:
The RP512EZ16 enables to define the end-of-line resistance of its zones. Selection is done via the panel keypad or
Configuration Software with the following available options
No
EOL
0
Customized
1
2.2K
2
4.7K
3
6.8K
4
10K
Technical Information
Current Consumption
Main Panel Connection
Dimensions
RTTE Compliance Statement:
Hereby, RISCO Group declares that this equipment is in compliance with the essential requirements and other relevant
provisions of Directive 1999/5/EC.
For the CE Declaration of Conformity please refer to our website: www.riscogroup.com.
© RISCO Group 07/2015
EN
RISCO 16 Zone Expander
DEOL
No
5
2.2K (Default)
6
6.8K
7
2.2K
8
10K
9
20 mA typical, 100mA Maximum
4-wire BUS, ≤300 m from Main Panel
16.5 cm x 6.6 cm x 1.8 cm
(RP512EZ16)
EOL
DEOL
No
3.74K
6.98K
10
2.7K
2.7K
11
4.7K
4.7K
12
3.3K
4.7K
13
1K
1K
14
EOL
DEOL
3.3K
3.3K
5.6K
5.6K
2.2K
1.1K
2.2K
4.7K
4.7K
6.8K
TEOL
12K
5IN2351 B

Publicidad

loading

Resumen de contenidos para Risco RP512EZ16

  • Página 1 Tamper Bypass between the TMP/COM terminal block) Zone Termination Note: The RP512EZ16 enables to define the end-of-line resistance of its zones. Selection is done via the panel keypad or Configuration Software with the following available options DEOL DEOL DEOL TEOL Customized 3.74K...
  • Página 2 TMP e COM Terminazione delle zone Nota: L’ espansione RP512EZ16 permette di impostare il valore delle resistenze di fine linea sulle sue zone. La selezione avviene tramite tastiera o software di Configurazione scegliendo tra le seguenti opzioni quella desiderata: DEOL...
  • Página 3 Exclusion AP bornes TMP/COM Câblage des Zones Note: Le RP512EZ16 permet de définir la valeur des résistances de fin de lignes utilisées pour les zones. Cette sélection est faite via le logiciel, avec les options suivantes disponibles : DEOL DEOL...
  • Página 4 TMP y COM). Terminación de Zonas Nota: El RP512EZ16 permite definir el valor de la resistencia de final de línea de sus zonas. La selección se realiza a través del software, con las siguientes opciones disponibles: Nº DRFL Nº...