VAL 300
3.3.2
Calibrating X axis
See graphic: wc_gr004594
The laser must be calibrated to bring the beam to the center of the two
X marks. Read "Calibration Overview" before proceeding.
3.3.2.1
3.3.2.2
3.3.2.3
3.3.2.4
3.3.2.5
3.3.2.6
3.3.2.7
3.3.2.8
If you are not sure of the calibration, don't save it and turn the laser off
using the ON / OFF key.
wc_tx000805gb.fm
Turn off the laser.
Hold the MAN key (12). While holding, momentarily press
the ON key (8).
After the LEDs blink in sequence, release the MAN key.
X LED will blink rapidly, indicating leveling. When the LED
blinks slowly, the laser is ready to calibrate.
If you have not moved the laser, use the X marks made in
previous steps of "Checking X axis".
Use the arrows on the keypad to move the beam up or
down to the halfway mark. If the X axis is toward the wall
with the marks, use the ^ key (15) to raise the beam, and
the v key (16) to lower the beam.
After completing the X calibration, press the H.I. Alert
Function key (10) to change the axis and to calibrate the Y
axis. (On the remote, press the double arrow key >>l)
If the Y axis doesn't have to be calibrated, press the MAN
key to save the calibration you've just made on the X axis.
(On the remote, use key with the small dot.)
EN-22
Maintenance