TANKLESS WATER HEATER ISOLATION VALVE KIT INSTALLATION GUIDE
1. Remove the COLD water isolation valve assembly
(identified by the blue handles) from the box.
Disassemble the union connection by loosening the
union nut and removing the tailpiece and gasket.
Ensure that all of the components are present: ¾"
or 1" FNPT tailpiece, gasket, union nut and steel
retaining ring (installed onto the valve body). NOTE:
the union nut is permanently mounted to the valve
body. See photo A
2. Connect the valve assembly's ¾" or 1" FNPT, or
sweat inlet, to the cold water supply line. Apply
thread sealant to the pipe nipple's external threads.
Use the appropriate flux and solder and verify that
the isolation valves are in the open position before
sweating onto the copper tubing. Make sure to
position the valve in a way that the handles are
accessible for operation without any obstruction.
This will typically result in the drain valve's capped
hose threads facing outward toward the user.
See photo B
3. Using the thread sealant recommended by the water heater manufacturer, thread and tighten onto the
water heater's COLD water inlet.
4. Verify that the gasket is centered in the tailpiece. Reconnect the union to the now-installed tailpiece. Brace
the tailpiece and tighten the union nut with the appropriate wrenches.
5. Remove the HOT water isolation outlet valve
assembly (identified by the red handles) and the
pressure relief valve.* Apply thread sealant to
the male threads on the pressure relief valve in
accordance with the water heater manufacturer's
or local code requirements. Install and tighten the
pressure relief valve into the ¾" FNPT connection
located next to the drain valve. Position the outlet of
the pressure relief valve in a downward position. See
photo C. IMPORTANT: Please refer to the additional
instructions for the pressure relief valve. Be careful
not to overtighten the relief valve. Do not tighten
more than two turns past hand tightened.
*Pressure relief valve supplied in some kits
Photo A
Photo B
Photo C
(Continued on next page)
English
1

Publicidad

loading

Resumen de contenidos para Jones Stephens D05001

  • Página 1 TANKLESS WATER HEATER ISOLATION VALVE KIT INSTALLATION GUIDE English 1. Remove the COLD water isolation valve assembly (identified by the blue handles) from the box. Disassemble the union connection by loosening the union nut and removing the tailpiece and gasket. Ensure that all of the components are present: ¾”...
  • Página 2 INSTALLING THE GAS CONNECTOR*: *Furnished in select Jones Stephens installation kits WARNING: Gases can be ignited by a spark or flame which may result in property damage, personal injury and/or death. Do NOT reuse connectors or join connectors together. Turn off gas supply at a gas ball valve near the appliance.
  • Página 3: Start Up And Normal Operation

    TANKLESS WATER HEATER ISOLATION VALVE KIT INSTALLATION GUIDE START UP AND NORMAL OPERATION: 1. CAUTION! Before pressurizing the system for service, make sure that the drain valves on both the HOT and COLD service valves are put into the fully CLOSED position.
  • Página 4 TANKLESS WATER HEATER ISOLATION VALVE KIT INSTALLATION GUIDE 5. Follow the manufacturer’s guide for attachment of the drain lines and specifics for flushing the water heater. To open the valves, rotate the handles until they are parallel with the valve body. 6.
  • Página 5 INSTALACIÓN DEL CONECTOR DE GAS*: *Se incluye en algunos kits de instalación de Jones Stephens ADVERTENCIA: Los gases pueden encenderse por una chispa o una llama, lo que podría provocar daños en la propiedad, lesiones personales y/o la muerte.
  • Página 6 GUÍA DE INSTALACIÓN DEL KIT DE LA VÁLVULA DE AISLAMIENTO DEL CALENTADOR DE AGUA SIN TANQUE 11. Para purgar el aire de la línea de agua, abra un grifo (en el punto más alejado del aparato) y luego abra el suministro de agua.
  • Página 7 GUÍA DE INSTALACIÓN DEL KIT DE LA VÁLVULA DE AISLAMIENTO DEL CALENTADOR DE AGUA SIN TANQUE 4. Las manijas de las válvulas de aislamiento deben permanecer en la posición TOTALMENTE CERRADA en condiciones normales de funcionamiento. Las manijas roja y azul deben estar paralelas al cuerpo de la válvula y la tubería.

Este manual también es adecuado para:

D05101D05102