1. Product features:
1) Super silent: its unique design eliminates noise.
2) Energy saving: thanks to ceramic technology, energy consumption is less than 1KW a month.
3) Stable and long lasting: no transmission parts or wear. Stable pressure and volume.
4) User friendly: Plug & play. No type of repair or maintenance.
5) With rear suction pad for easier fixture.
2. Technical parameters:
Model Voltage Frequency Power
Flow
Pressure
Noise
Diameter
MCI1
220V
50Hz
1,0W 0,45L/min
12Kpa
<35db
52mm
MCI2
3. Installation Instruction:
Power
Power
Line
Line
Pump
Pump
Figure 1
Figure 2
Pump
Check Valve
Power
Power
Line
Line
Porous Stone
Pump
Figure 3
Figure 4
4. Aspects requiring special attention:
1) Do not submerge it in water.
2) If the pump has been submerged in water, please cut off the power supply immediately.
3) Clean the pipe and diffuser stone regularly, as they receive the greatest flow of air. This will extend the working
life of the pump.
4) For your safety: if you see that the power cable is damaged, do not use this product.
5) Before placing your hand in the water, please make sure you cut off the power supply to the air pump.
6) The position of the pump must be above the surface of the water (Figure 3). If it is placed below the surface
of the water, an anti-return valve must be installed on the pipe to prevent the pump from flooding with water
(Figure 4).
5. Solutions for additional problems:
Situation
Abnormal functioning
Water
Recommended
Column
Aquarium
Low volume
<=60cm
<=100L
High temperature
Abnormal sound
Tube
PRODUCT WARRANTY CARD
Thank you for choosing our products. Please read the following warranty carefully.
1) Please keep the warranty and show this card when the warranty service is required.
2) With normal use, the product has a warranty period of two years as of the date of purchase.
Porous Stone
3) Abnormal damage, such as natural disasters, are not covered by the warranty.
4) Please use the parts supplied by our company.
5) The table below must be correctly completed by our agents and representatives.
Tube
GB
Porous Stone
2
IMPORTED AND DISTRIBUTED BY: ICA, SA. CIF A-35031343. Pol. Ind. Monte Boyal, 45950, Parcelas 242-247, Casarrubios del Monte
(Toledo) España España (+34) 918 170 001 - Portugal (+351) 311 943 162. Fabricado en China. www.icasa.com
Check
Method of elimination
That the power is on and
Check the voltage
the requirements are met
Replace the pipe or
Air pipe broken or kinked
position appropriately
Replace the air
Air pipe or diffuser blocked
pipe or diffuser
That the installation is correct
Correct installation