2. OPERATING INSTRUCTIONS
WARNING:
2.1 OPERATION WITH THE GAS CONTROL VALVE
Operate the appliance with the gas control valve located behind the door.

2.2 TURNING ON

1. Push the control knob and turn counterclockwise to the ignition position. You will
hear a click, which is the spark to turn on the pilot burner.
2. Keep the control knob depressed for 10 seconds when the pilot light is on. Then let go
of the control knob and turn it counterclockwise fully.
3. In case the pilot light goes off: repeat step 1 and 2 until the pilot light stays on.
WARNING:
detector spray on all gas fittings/connections. There is a leak if air bubbles
appear as result of the gas leak detector spray.
WARNING:
if alight, the gas supply shall be shut off and the appliance shall be investi-
gated and rectified before it is used again.
WARNING:
tilting of the appliance.

2.3 ADJUSTING THE FLAMES

1. Set the desired flame height by turning the flame height knob.
2. Turn the knob clockwise for a lower position.
3. Turn the knob counterclockwise for a higher position.

2.4 TURNING OFF

Turn the control knob back to the same position as the image.
WARNING:
6
Read the instructions before use.
Check all gas connections on leakage before use. Use gas leak
In the event of gas leakage, the appliance shall not be used or
In case of violent wind precautions must be taken against
Close the gas cylinder or pressure regulator after use.