COZY C255H Manual Del Propietário página 24

Ocultar thumbs Ver también para C255H:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

WARNING: Danger of bodily injury or death. Turn off
electric power supply at disconnect switch, fuse box
or service panel before removing any doors or access
service panels from unit.
ANNUAL UPKEEP NEEDED
It is recommended that a qualified service technician perform
these maintenance checks at the beginning of each heating
season.
CABINET FINISH
Clean cabinet with damp cloth. Never use abrasive cleaners.
Cabinets are finished with heat resistant powder paint. Never
refinish or paint.
FURNACE AREA
Keep the area near the furnace clear and free from combustible
materials, gasoline and other flammable liquids and vapors.
COMBUSTION AND VENTILATION AIR
The combustion and ventilation air supply must not be blocked.
Do not put anything in or on the furnace cabinet. For better
circulation and more effective heating, do not place obstructions,
furniture or other items closer than four&feet in front of the
furnace or two&feet from each side of the furnace.
CLEANING BLOWER (IF APPLICABLE)
Shut off electricity. Clean any lint or dirt from fan blades, fan
motor and exposed air passages.
PILOT BURNER
Using the instructions in Lighting the Pilot , leave thermostat at its
lowest setting. Pilot flame should surround the generator tip 1/4 to
3/8-inches. If flame needs adjusting, do so as follows:
1.
Insert small screwdriver into the pilot adjusting screw
Figure 23. Adjust flame as needed. Turn screw
counterclockwise to increase flame, clockwise
to decrease.
2.
Turn thermostat to highest setting. Main burner should
light quickly and smoothly. Turn thermostat to lowest
setting. Main burner should go out. Pilot should remain lit.
FIGURE 23 - ADJUSTING THE PILOT
24
COZY TOP VENT GRAVITY GAS WALL HEATER
HOW TO CARE FOR YOUR FURNACE
VENT SYSTEM
Make sure that no parts of the venting system are blocked or
rusted. Clean or replace before using the furnace.
BURNER CLEANING
If cleaning is required, contact a qualified service technician to
clean and service burner. To remove burner(s):
1.
2.
3.
4.
5.
6.
7.
FIGURE 24 - DISCONNECTING GAS LINE
CLEANING THE BURNER COMPARTMENT
Because cold air is attracted to the flame during furnace
operation, a buildup of lint from carpeting, bedding, dust, etc.
in the burner area will occur. It is necessary to clean this area
regularly. Use a vacuum cleaner with a narrow attachment to
reach small areas. Be careful in and around the pilot. A change
in its adjustment could be made if moved during cleaning. A
properly adjusted burner with nearly all gases will produce a
flame which has clear blue cone having a bluish-red or bluish-
violet outer mantle.
Open burner compartment door.
Shut off gas supply to furnace.
Disconnect gas line inside cabinet at ground joint union
fitting. Figure 24
Remove (2) screws securing burner pan assembly to
inner liner.
Pull burner pan assembly forward approximately
1/2-inch and drop down to expose the top of the burner.
Clean all foreign materials from the top of the burner.
After cleaning, replace burner pan assembly by
reversing above procedure.