PARTS DESCRIPTION
USE AND OPERATION
POWER
1. Connect the cord to a power outlet. The Power LED icon will
glow in amber indicating the power source is connected.
2. Press the POWER button to turn on the unit. To turn off
the unit, press the POWER button again. When the POWER
button is pressed, the Power LED icon will change color from
amber to red and the blue fan LED icon will come on. The
cooler will start in fan mode at medium speed then drop to
the low speed setting.
SPEED
Press the SPEED button to select the desired fan speed. The
selected fan speed indicator LED will come on.
H = High speed
M = Medium speed
L = Low speed
COOL
To use the unit as an evaporative cooler, press the COOL button,
the pump will turn on and distribute water to wet out the cellulose
cooling pad located in the rear of the unit. The indicator LED
light will come on. After approximately three minutes, as the
pad becomes saturated, the air from the outlet should be cool.
To order, call 1-800-642-2112
LOW WATER ALARM FUNCTION
The KA45 is equipped with a low water sensor alarm. When
water in the tank is below minimum level, you will hear 10
beeps and COOL LED indicator will flash continuously. At the
same time the power to the pump will be cut off to protect the
life of the pump. In order to disengage the alarm function, turn
off and unplug the unit from the power outlet, and fill the tank
with water above the minimum level. In order to turn off the
alarm function and continue to use it in FAN mode, turn off the
unit and turn the unit back on. If COOL button is pressed again
without filling the tank with water, low water alarm will go off
again.
TIMER
The unit comes with a maximum 7.5-Hour timer. Each time TIMER
button is pressed 0.5 hour of operation time is added. The sum
of all illuminated LED indicates the remaining operation time.
EX: „2‟ and „4‟ lights illuminated meaning there are 6 hours
remaining before unit shuts off.
SWING
Press the SWING button to direct the air stream. The louvers will
begin to move automatically from side to side. The indicator
LED will come on.
UP-DOWN AIR FLOW
To adjust the vertical direction of air flow, adjust the horizontal
louvers located behind the front grille manually.
If you have any questions regarding this product, call 1-800-642-2112 and ask for our product
specialists (Mon.-Fri. 9:00 am – 5:00 pm EST) or email:
See many more products on the Internet!
productspecialist@improvementscatalog.com
www.improvementscatalog.com
3