1. Disconnect the building-side connecting
cable from the power supply and secure it
against being switched on again. To do
this, trip the corresponding circuit breaker
of the house installation.
Remove the lamp (1) from the mounting
pot (2).
3. Guide the connection cable on the
building side through the cable opening of
the installation pot (2). Then place the
installation pot (2) in the installation
opening (4) provided for this purpose.
4. Connect the connection cable (3) of the
luminaire to the connection cable on the
building side. The cables must be
connected in a watertight manner (e.g. with
a cable sleeve).
Then place the lamp (1) in the mounting
pot (2).
6. Turn the power back on. The installation
is now complete.
Subject to technical changes
LEDs Com GmbH, Dohrweg 2a, D-41066 Mönchengladbach, www.leds-com.de, Tel. +49 (0) 2161 - 5 75 99 76
English
Ground recessed light (LC-EL-085-WW) - Assembly instructions
Figure 1
1: Luminaire
2: Installation pot
Figure 2
3: Connection line
4: Installation opening
04/2022