INSTALLATION AND
MAINTENANCE INSTRUCTIONS
SS-HB-3
General Information
PLEASE READ THIS INSTRUCTIONS MANUAL THOROUGHLY AND CAREFULLY
AND UNDERSTAND ITS CONTENTS BEFORE INSTALLING THE FILTER HOUSING.
- The information in this instruction manual is subject to modifications without prior notice.
- Keep the instruction manual for future reference.
Product Identification:
The sticker and the label must not be removed, tampered with, hidden, covered,
or changed.
WARNING: The values of the maximum working temperature and the
maximum working pressure shown in the label affixed to the filter
housing are intended as maximum working parameters.
Precautions, Warnings
READ ALL INSTRUCTIONS AND PRECAUTIONS BEFORE INSTALLING AND USING
THIS PRODUCT.
- Before installation ensure that any electric plugs in the vicinity of
the area are disconnected.
- Before the installation, carefully lubricate the housing o-ring which
is located at the sump top.
- Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after the
system. Systems certified for cyst reduction may be used on
waters that contain filterable cysts.
Installation
Refer to figures:
A General information.
B IN - OUT directions presentation in different filter housings models.
C Installation lay-out (next page):
1. Water mains | 2. Pressure reducer | 3. Anti-water hammer device
4. Other utilities | 5. Filter unit of any model
- Before installation, check if the plumbing system has been constructed according to
the applicable plumbing code.
- Avoid all kind of stress by using a wall bracket. Should the use of the wall bracket be
impossible, the installer (qualified and licensed personnel) shall be responsible for the
most appropriate installation avoiding stress which may affect the housing's integrity.
- Connect the inlet to the product's side with the arrow IN and the oulet to the side
with the arrow OUT. (Fig. B)
- Connect to pipes using tapered fittings, preferably with flexible hoses.
These instructions apply to the filter housing as specified in
the package sticker. A label describing working conditions
is applied to the filter housing.
Turn-off the water main before installation.
US
1