10. Technical specifications

– Dimensions (H × W × D):
– Voltage range:
– Typical DALI current consumption (at 16.5 V):
– Max. DALI current consumption
(starting current at 22.5 V):
– DALI-2 addresses:
– Input via:
– Number of inputs:
– Input terminal labelling:
– Max. cable length:
– Max. housing temperature:
– Protection class: II. When used in the intended manner
– IP rating:
– Ambient temperature:

11. Troubleshooting

Unit without power.
– Fuse not switched ON or faulty.
• Switch ON fuse.
• Change faulty fuse.
– Break in wiring.
• Check wiring with voltage tester.
– Short circuit in mains power supply lead.
• Check connections.
– Any mains switch OFF
• Switch ON mains switch.
49.8 × 43.0 × 15.1 mm
(in accordance with IEC62368-101)
floating push-button/switch
– 16 –
9.5 VDC - 22.5 VDC
K1, K2, K3, K4
-20°C to +50°C
2.7 mA
9 mA
1
4
50 cm
75 °C
IP 20