The indicator contains two main setup menus:
The Setup ("P") menu
This configures the indicator to the weigh platform
The User ("S") menu
This configures the serial communication port and enables some user options.
The Setup and User menus consist of several menu selections, each with its own sub-menu.
To set up the indicator, first select the appropriate menu mode. Keys [UNIT], [ZERO],
[TARE] and [PRINT] become direction navigators (as indicated by the arrows above them)
to move around the menus and the [NET/GROSS] key is used to save or SET the
selections.
2.1 SET UP ("P") MENU
a. Switch off the indicator.
b. On the rear panel, move the Calibration/Setup Switch to the "Setup" position. Left is
calibration mode, right is weighing mode.
c. Switch on the indicator. The indicator will display "P 1" to indicate that it is in Setup P
menu mode.
Use the direction keys to navigate around in the Setup Menu Chart.
a. To move to a new "P" heading, use the [TARE] (left) or [PRINT] (right) key to navigate the
Setup Menu Chart.
b. To move to the selection level, press the [ZERO] (down) key once. The current saved
selection is shown.
c. To view the available selections for the current "P" heading, use the [TARE] (left) or
[PRINT] (right) key to navigate through the selection field.
d. To save a new selection, press the [NET/GROSS] (Set) key .To exit without saving, press
the [UNITS] (up) key to return to the current "P" heading.
e. Repeat Steps 1 through 4 until the Setup Menu is programmed.
PS-IN202 (SS) Indicator
All manuals and user guides at all-guides.com
Chapter 2
Configuration
- 5 -