www.evolutionpowertools.com
PRESSURISING THE TANK
Hand pump:
•
Press down and turn the handle until it is in the middle
position to unlock the handle. (Fig. 1)
•
Pressurise the tank by moving the pump handle up and
down, approximately 10 times.
•
To lock the handle after pumping, simply push the handle
down in the middle position and turn the handle ¼ turn until
it locks into position.
Foot pump:
•
Remove the valve cover from handle and attach the foot
pump to the handle assembly valve.
•
Push the pump connector on to the valve and lift the
lever upwards, be sure the fitment is not leaking before
pressurising the tank. (Fig. 2)
•
Pressurise the tank by pumping the foot pump, to unlock
the foot pump push the foot plate down slightly to take the
spring pressure then slide the two locking buttons to the
unlock position.
WARNING: Do not exceed 3 bar or 45 PSI.
DEPRESSURISING THE TANK
Unscrew the pump unit from the tank to release the air pressure.
This should be done before filling and after finishing work.
WARNING: Do not leave the tank pressurised for long periods
when not in use.
WARNING: Do not leave the tank pressurised and in direct
sunlight for prolonged periods.
MAINTENANCE
When not in use drain the hose of any residual water. Keep the
tank and parts clean and free of debris.
Fig. 1
Fig. 2
3
EN