Mobile air conditioner 7000 BTU
545144072
Sleep Mode
Sleep mode can only be activated in COOL mode.
After 1 hour, the set temperature will increase by 1 ℃, after another hour, the set temperature will increase by 1 ℃.
In COOL mode :
Timer:
The timer can be operated in two ways:
To turn off the unit:
Press the timer button to activate the timer function. Press UP/DOWN repeatedly to determine the duration.
To turn on the unit:
Press the Timer button to activate the timer function. Press UP/DOWN repeatedly to determine the duration.
To cancel the timer: Press the UP/DOWN button repeatedly until the LED indicates '00'. Note: The timer can also be
turned off by pressing POWER.
Automatic defrosting
At low room temperatures, frost can accumulate on the evaporator. The unit will then start defrosting automatically
(POWER LED flashes).
Overload protection
In the event of a power failure, the compressor is protected by a delay of 3 minutes until the unit restarts.
Self-evaporating system and water tank
The self-evaporating system uses the collected water to cool the condenser coils for better performance. The
condensation water evaporates at the condenser and is discharged through the exhaust hose.
•
Turn off the device before using it.
Remove the plug from the water
outlet and keep it in a safe place.
Connect the drain hose securely and
securely, making sure it is not kinked
or clogged.
Place the drain hose over a drain or
bucket and allow water to flow freely
out of the unit.
Do not immerse the end of the hose
in water as this may cause "Air Lock"
in the hose.
Prevent water leakage:
As the underpressure of the condensate drain pan is high, tilt the drain
hose downwards towards the floor. The slope should be more than 20
Remove the rubber plug.
Drain hose
(Inner diameter=16mm)
EN - 6