MANUAL RESET PROBLEMS
The control will signal, with a certain number of flashes of the enablement Led, the presence of any manual reset prob-
lems. Together with the flashes a short sound can be heard.
What follows is the correlation table between the flashes and the manual reset problems:
N. OF FLASHES PROBLEM
Overload on the
1
command electrical
line
Interruption on the
2
command electrical
line
The resetting of this class of problems occurs, once the cause that has generated them has been removed, by switching
off and switching back on the remote control.
MAINTENANCE
The control panel needs no particular maintenance. To ensure optimum performance from the equipment, once a year
check the cables and the electrical connections.
Clean the control panel with a soft cloth dampened with water. Do not use chemical or abrasive products to clean the
control panel.

TECHNICAL DATA

OUTPUT CHARACTERISTICS
Current capacity of UP or DOWN windlass control
INPUT CHARACTERISTICS
Supply voltage (1)
Quiescent current (2)
Maximum current absorption (3)
AMBIENT CHARACTERISTICS
Operating temperature
Protection rating (4)
GENERAL CHARACTERISTICS
Dimensions including frame (L x L)
Weight
EMC class
(1) With power supply voltage less than 8 Vdc the control panel can reset.
(2) Typical value with control panel disabled.
(3) Typical value with control panel enabled and one direction button pressed.
(4) Excluding the back of the control panel (IP20).
Quick
®
reserves the right to modify the technical characteristics of the equipment and the contents of this manual without prior notice.
WCD 1022 REV001A
SYSTEM PROBLEMS / MAINTENANCE / TECHNICAL DATA
DESCRIPTION
The problem is signalled when the control detects a short circuit or an overload on the com-
mand electrical line of the windlass. Check the wiring of the electrical line of the remote control
to the windlass and the absorption of the remote control switches installed on the windlass.
The problem is signalled when the control detects an interruption on the command electrical
line of the windlass.
Check the wiring of the electrical line of the remote control to the windlass.
55 mA + absorption of remote control coil
EN 60945 - FCC TITLE 47 Part 15 SUBPART B CLASS B
4A max
from 8 to 31 Vdc
10 mA
from -20 to +70 °C
IP66
78 mm x 78 mm
80 g
EN
15