Descargar Imprimir esta página

Hessaire ES14: 2160 CFM Manual Del Usuario página 2

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation Steps
Step 1) Locate and cut square hole in interior wall between wall studs. Drill a small pilot
hole in each of the four corners going through to the exterior wall. (Locator holes assist
in cutting exterior shutter opening hole)
Step 2a) Option #1: Run incoming power to lower right corner of opening where switch
knob will be located. Speed control is already factory installed in lower right corner of
fan housing. Connect wires to speed control. Speed will be controlled by switch on fan.
Step 2b) Option #2: Install control in wall. Remove speed control from corner of fan
housing and install in junction box on wall. Bring incoming power to junction box. Con-
nect wires according to the wiring diagram. Speed will be controlled by switch on wall.
Step 3) Place fan housing in opening—guiding wiring up through access hole in lower
right hand corner of housing. Fasten fan in place with 4 #10 screws. Connect wiring.
Step 4) Snap protective cover in place using spring clips in upper and lower fan housing
slots.
Step 5) From exterior wall, cut square opening through wall using 4 locator holes to
mark corners.
Step 6) Place shutter in wall with louver hanging down. Shutter frame will fit over fan
housing. Fasten in place with 4 #10 screws.
Exterior Wall
5
6
Weather
Shutter
ES14 Manual Online 031622
Exterior Steps
Fasten to siding using
#10 screws—provided
#10 Screws X 4
3
Wiring Diagram
(Black)
L
AC 120V / 60Hz
WARNING:
Electrical connections must be
(White)
N
done by qualified personnel in
accordance with all applicable
(Yel/Green)
electrical codes. Unit must be
G
properly grounded.
Operation
Turn speed control knob clockwise to increase speed of fan.
Turn counter-clockwise to decrease fan speed.
Turn speed control knob fully counter-clockwise to shut unit off completely.
Parts Illustration
Ref. #
Replacement Part Description
1
Motor
2
Propeller
3
Front Grill
4
Speed Control Knob
5
Speed Control Cap Cover
6
Winter Grill Cover
7
Fan Housing
8
Weather Shutter
9
Variable Speed Controller
10
Wall Switch Plate
Problem
Cause / Remedy
Ensure unit is plugged in and switched on.
Receptacle breaker may need to be reset.
Fan will not turn on
Make sure nothing is obstructing fan blade.
Fan motor may need to be replaced.
Control switch may need to be replaced.
Fan Intake or discharge shutters are obstructed
Fan runs slow
May need to replace capacitor
Red
AC
Control
Black
Fan
White Common
Motor
Yellow/Green Ground
Part #
E050-4E
6001308
Note: Please contact the dis-
E14FG
tributor where you purchased
E14K
the fan with any questions
E14CC
regarding the fan or if you are
E14WG
in need of replacement parts.
E14FH
E14WS
VSC14
E14SP
Troubleshooting
Visit
www.hessaire.com
for warranty
information
4
Hessaire.com
Black

Publicidad

loading