VISUAL GUIDE for use
I
II
60
55
At least 2 minutes per
50
setting unless prescribed
45
differently.
40
35
30
III
Inhale through the
nose, if possible.
IV
V
The initial pressure applies to both settings I and II
Level A: 4 cm/H
Level B: 7 cm/H
Level C: 10 cm/H
Level D: 16 cm/H
VI
18 | EN
Setting I
Setting II
TIP:
Start with setting
II to simplify your
entry into respiratory
5
therapy with the
10
RC-Cornet
15
20
25
Exhale through
the device.
Inhale slowly and steadily,
and exhale after a brief pause.
O
2
O
2
O
2
O
2
'Huffing', cough up phlegm.
INSTRUCTIONS for use
I
Please inspect the device for foreign bo dies or damages
prior to use. If any parts are missing or da ma ged, replace
them immediately.
II
Settings: RC-Cornet
of treatment. Select the treatment options using the settings
I or II on the mouthpiece. Change the settings by turning the
mouthpiece. Please turn the mouthpiece to the stop. Unless
otherwise prescribed, use both settings for at least two minutes
each. Always start therapy with setting I.
• Setting I: Stabilizing PEP
- enlarges airways, promotes collateral ventilation and
reduces shortness of breath.
• Setting II: Mobilising PEP
bronchial mucus. This makes coughing more productive.
PLUS.
®
Once the airways have been cleared, the urge to cough
automatically diminishes.
III
Hold the device as shown. Insert the RC-Cornet
the mouth and close the lips around it to ensure an effective
seal. Please do not bite on the mouthpiece or block the
nebulizer port your hand. Breathe in through nose or mouth
and after a brief pause, exhale through RC-Cornet
a normal rate and intensity.
IV
Exhaling into RC-Cornet
sure in the lower respiratory tract as well as vibrations. As
you become used to breathing out through the RC-Cornet
PLUS, take deeper breaths and exhale after a brief pause
all of the air through the RC-Cornet
exhalation phase should take at least 3-4 times longer than
inhalation. TIP: Use your free hand to press your cheeks
together to avoid a loss in pressure and to maximise treatment
effectiveness.
V
In addition to the settings described under II, 4 different levels
of resistance can be selected for each setting. This allows an
individual patient suitable training by choosing the right level
of resistance (outlet pressure). Start with level A and increase
the levels for each condition. Set the levels by turning the
body against the adapter. Please verify the therapy with your
healthcare professional.
VI
If you feel like phlegm is in or blocking your air passages, try
to exhale as long as you can through RC-Cornet PLUS and
to suppress coughing. If you still need to cough, try to huff
up phlegm. Imagine you want to fog up a pane of glass or a
mirror. By exhaling this way (medical term "huffing"), you can
better expel mucus from the bronchial airways. Please do not
cough or expel phlegm into the device.
PLUS can be used for two different forms
®
(positive exhalation pressure)
TM
- frees the airways from thick
TM
PLUS produces a positive pres-
®
PLUS. Ideally the
®
PLUS into
®
PLUS at
®
®
EN | 19