LOCKING SELECTION(S)
The Hydom 2RU* hydraulic motor is factory configured as a non-locking hydraulic motor.
To configure other options, one or both of the locking selection valves must be closed. The valves are located on the side of the unit and are
operated with a 4mm Allen key (see figure 10).
Type of door
Type of locking
Valve A
Valve B
SPEED REGULATION(S)
The Hydom 2RU* hydraulic motor is supplied with a quick opening and closing speed pre-adjustment.
To regulate the speed, a 2.5mm Allen key must be used to screw the throttle on each side of the unit (see figure 11).
•
Strangler A → Regulates the opening speed for doors type "C" and the closing speed for doors type "A" and "B".
•
Strangler B → Regulates the closing speed for doors type "C" and the opening speed for gates type "A" and "B".
FIG. 10
No
Double
locking
locking
Open
Closed
Open
Closed
FIG. 11
•
Closed bypass → Screw until it stops.
•
Open bypass → Once bypass is open,
unscrew one and a half turn.
Mounting type "A" and "B"
Locking on
Locking on
open door
closed door
Open
Closed
Closed
Open
-
-11
CAUTION: loosening any of
the valves too much could
cause oil leakage and
render the equipment non
operative.
Mounting type "C"
Locking on
Locking on
open door
closed door
Closed
Open
Closed
CAUTION: When loosening the adjusters,
do not allow them to stand out from the
wall of the equipament; this could cause
oil leaks and render the equipment non
operative.
REGULATE by 1/4 to 1/4 turn.
Open