SIGNALS
- Does not fasten the rivet
- Air leak
- Not ejected nail
44
GB
TROUBLE SHOOTING
CAUSE
- Non-powered tool
- Slipping of the clamps on the nail
- Incorrect nozzle
- Unfiltered and unlubricated air
- Incorrect positioning of the
feeding tube
- Worn gaskets
- Breaks on the riveting machine
body
- Incorrect nozzle
- Closed suction system
- Full nails container
750301 - RAC 83 AX – rev 10 - ( 12-2021 )
SOLUTIONS
- Connect the riveting tools to the
compressed air
- Perform clamps maintenance
- Replace the nozzle as shown in
the table
- Equip yourself with lubricator
filter assembly
- Position the feeding tube correctly
- Contact the service center
- Contact the service center
- Replace the nozzle as shown
in the table
- Open the suction system
- Empty the container
RAC 83 AX