INSTALLATION
Warning : If tipped more than 45° during transportation, allow the unit to set upright for at
least 24 hours before starting up.
Selection of the location
Install the portable air conditioner in a well
•
ventilated room of min 12m², on a flat and dry
location, without obstacles.
Leave a 50cm minimum space around.
•
Place carefully the power cord in order to
•
prevent someone from tripping and pulling out
the plug accidentally.
Adjust gently the upper and lower air swinging
•
guides.
Exhaust pipe
Fix the exhaust pipe into the adapter, and then
•
fix the other side into the air outlet vent of the
unit. (anti-clockwise) (Fig 2).
Fix the adapter into the window slider kit, then
•
half open the window to meet the width of the
window slider kit.
The length of the window slider kit is adjustable.
•
Warning : Take care to prevent any bows or bends
of the exhaust pipe. The exhaust air must flow freely.