Electrical Diagram; Operation Of The Wine Cooler - Oster OS-WC04SC Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Input
Power

OPERATION OF THE WINE COOLER

• The temperature is set in the range of 8 °C - 18 °C in the cabinet.
• When the power is switched on, the cooling system starts to operate. The TEMP-ADJ button
is set to a certain position, which means that if the temperature in the wine cooler reaches the
set point, the Auto Temperature Control System stops the cooling system so that the
temperature in the cabinet gradually rises.
• When the inside temperature rises above the set point, the Auto Temperature Control starts
working again, the wine cellar enters cooling circles.
• When you want to change the cabinet temperature, you can press "Temp +" and "Temp -" on
the left to increase and decrease the temperature.
• You can press "C/F" button on the right to switch between Celsius and Fahrenheit or press
"LIGHT" button on the right to control the interior light.
NOTE:
After adjusting the temperature, the LCD display will return to show the temperature in the
refrigerator, but it may rotate to the point you have gradually adjusted.

ELECTRICAL DIAGRAM

Power Supply / Temperature Control
Panel
English-3
NTC Temp.
Heat Sink Fan
Thermoelectric Module
Cooling Heatsink Fan
Display