1. Disconnect the building-side connecting
cable from the power supply and secure it
against being switched on again. To do
this, trip the corresponding circuit breaker
of the house installation.
2. Remove the lamp from the mounting
pot (1). Loosen the two screws (2) on the
back of the light and remove the light cover
(3).
3. For mounting with installation pot (1),
you must pierce or cut a cable opening in
the installation pot at one of the
perforations (4) provided for this purpose.
Then guide the connection cable on the
building side through the cable opening
and place the installation pot (1) in the
installation opening provided.
Guide the building-side connection cable (6
- 9 mm cable diameter) through the
opening (5) on the back of the light.
5. Connect the building-side connection
cable to the luster terminal inside the
luminaire as shown in Figure 2.
6. Now close the lamp housing again.
7. Then place the light in the designated
location. The springs (6) on the side of the
light should now fix the light in place.
8. Turn the power back on. The installation
is now complete.
Subject to technical changes
LEDs Com GmbH, Dohrweg 2a, D-41066 Mönchengladbach, www.leds-com.de, Tel. +49 (0) 2161 - 5 75 99 76
English
Recessed wall light (LC-EL-124-WW) - Assembly instructions
Figure 1
1: Installation pot
2: Screws
3: Luminaire cover
Figure 2
4: Perforation for cable opening
5: Cable opening
6: Springs
05/2022